N-Tron
®
Series NT24k
®
Compact Hardware Manual
1-73
P
RODUCT
O
VERVIEW
R
EVISED
2017-09-11
NT24
K
-16M12-POE
D
RAWING
N
O
. LP0987-D
1.26.2
NT24k
‐
16M12
‐
POE
Specifications
Mechanical
Height
Width
Depth
Weight
Mount
5.90" (14.99 cm)
12.84” (32.61 cm)
3.19" (8.10 cm)
With Handles:
3.60” (9.14 cm)
5.5 lbs (2.49 kg)
Bulkhead
Power Input
Input Voltage
Steady Input Current
Inrush Current
BTU/HR
22-49 VDC
11.5 A @ 24 VDC
(240W combined load
on all PoE ports)
64.2 A /0.044 ms @ 24
VDC
123
Power over Ethernet (PoE)
PoE Standard
PoE Output Power
PSE Type
IEEE 802.3af/at Gigabit Endspan PSE
57 VDC / 30 Watts output (25.5 W at PD)
Type 2
Environmental
Operating
Temperature
Storage Temperature Operating Humidity
Operating Altitude
-40 to 80 °C
-40 to 85 °C
10% to 95% (non condensing)
0 to 10,000 ft.
Shock and Vibration
Shock
Vibration
Note
200g @ 10ms
50g, 5-200Hz, Triaxial
Unit must be bulkhead mounted to achieve these
levels.
Connectors
10/100/1000Base-T: 16 M12 X-Code Ports
Pin Assignments
POWER
L-Code
ETHERNET
X-Code M12
Recommended Minimum Wiring Clearance
Front
4" (10.16 cm)
BI_D4+
BI_D3-
RX_D2-
TX_D1-
BI_D4-
RX_D2+
TX_D1+
BI_D3+