N-Tron
®
Series NT24k
®
Compact Hardware Manual
2-95
H
ARDWARE
I
NSTALLATION
R
EVISED
2017-09-11
P
OWER
S
OURCE
D
RAWING
N
O
. LP0987-D
To
Remove
Wires
from
Terminal
Block
1.
Disconnect power to the unit and verify that the power LED remains Off.
2.
Remove the positive wire from the DC power supply by inserting a small screw driver or tool into the slot
adjacent to the positive wire and gently pulling on the wire being removed.
3.
Remove the negative wire from the DC power supply by inserting a small screw driver or tool into the slot
adjacent to the negative wire and gently pulling on the wire being removed.
4.
In the event redundant inputs are utilized, repeat the above steps by removing the positive/negative wires
from the V2+, V2- circular openings on the power connector.
General
Power
Supply
Notes
for
NT24k
PoE
models
•
NT24k PoE models, use 12-14 gauge solid or stranded wire with ferrules.
•
Voltage drop across the power wires between the source power supply and the NT24k unit should be
considered during installation. (~0.5V/10ft for 12 AWG wire, ~0.65V/10ft for 14AWG).
•
Failure to use proper wire may cause the following:
•
Unit does not power up properly or may cycle power on/off.
•
PoE ports being shut off
•
Excessive heat on the wire conductors may cause permanent damage.
•
Verify that the proper input voltage is connected to the NT24k before powering on the unit.
Never apply AC
power to a DC NT24k unit as it will permanently damage the unit.