R
EVISED
2016-01-19
Name
Data Type
Description
Link_Status_33
BOOL
1=active, 0=inactive
Link_Status_34
Link_Status_35
…
Link_Status_62
Link_Status_63
Link_Status_64
Utilization_Alarm
DINT
Bandwidth utilization alarms for first 32 ports. Also
available as port specific tags
Utilization_Alarm_1
BOOL
1=bandwidth utilization exceeds a high or low limit,
0=bandwidth utilization within limits
Utilization_Alarm_2
Utilization_Alarm_3
…
Utilization_Alarm_30
Utilization_Alarm_31
Utilization_Alarm_32
Utilization_Alarm2
DINT
Bandwidth utilization alarms for second 32 ports. Also
available as port specific tags
Utilization_Alarm_33
BOOL
1=bandwidth utilization exceeds a high or low limit,
0=bandwidth utilization within limits
Utilization_Alarm_34
Utilization_Alarm_35
…
Utilization_Alarm_62
Utilization_Alarm_63
Utilization_Alarm_64
Class1_Connections
INT
Number of CIP EtherNet/IP class 1 (multicast)
connections
Class3_Connections
INT
Number of CIP EtherNet/IP class 3 (unicast)
connections
Temperature_C
INT
Temperature in degrees Celsius. 0x7FFF = Not
supported on device.
Temperature_F
INT
Temperature in degrees Fahrenheit. 0x7FFF = Not
supported on device
CPU_Utilization
SINT
Percent of CPU usage, 0-100
Contact_Status
SINT
2 Bits per contact. 00=Not Present, 01=Open,
10=Closed
N-Tron® Series 700/7000 Switch CIP™ Manual
-26-