Service And Repair
Replacing the Packer-to-Manifold Wiring Connectors
38
Figure 35. Locating Female Connector Set Screw
22. Remove the manifold’s female connector o-ring.
23. Get the 0.862’’ ID x 0.103’’ wide o-ring from the connector kit and lubricate it with petroleum jelly. Insert this
o-ring in its groove in the manifold around the female connector (see Figure 30 on page 35).
24. Get the three extractable o-ring seals (3.975’’ ID x 0.210’’ wide [upper], 3.850’’ ID x 0.210’’ wide [middle],
and 3.725‘’ x 0.210’’ wide [lower]) from the hardware/seal kit. The three o-rings are very close in size so take
extra care to distinguish each one before replacing them in the extractable. Lubricate each o-ring with
petroleum jelly and then install them in their assigned grooves in the extractable (see Figure 25 on page 26).
25. Reinstall the extractable unit into the manifold and tank. Torque the extractable lock-down nuts in an alternating
pattern to 50 ft-lbs (68 N•m).
26. Turn the air purge screw 2 - 3 turns counterclockwise (see Figure 29).
The air purge screw is retained by a hitch pin to limit travel. Do not attempt to rotate
beyond 3 turns.
27. Turn the pump on and let it run for about 2 minutes to purge air from the manifold’s hydraulic cavities. While
the pump is still running, turn the air purge screw clockwise until it is completely closed.
28. If applicable, open the ball valve down line from the pump.
3/8'' hex set screw that
holds in female connector
Female connector sits
on ridge in bottom of
socket
Flat cut in side of connector
must face set screw
Male connector in
extractable housing
Female connector in
packer housing
rjpumps\fig34vsfc.eps
WARNING