12
Installation
Attaching the UMP
Table 6 lists the applicable UMPs for each packer/manifold.
The UMP is identified by the model number marked on the shell. The packer/manifold with piping is identified by
the catalog number on the packer nameplate. The hardware kit consists of four 5/16-18 socket head cap screws,
four 5/16 lock washers and one discharge head gasket identified by the kit number (144-327-4) marked on the
bag (see Figure 6).
The UMP attaches to the packer/manifold column piping discharge head using hardware kit number 144-327-4.
Figure 6. Packer/Manifold With Piping Attaching To UMP
1.
Visually inspect the pigtail connector in the end of the discharge head. Be certain the pigtail connector is
seated in its socket and its index tab is in the socket’s notch (see Figure 7).
Figure 7. Verifying Pigtail Female Connector Is Seated Properly
Table 6. UMP And Packer/Manifold Combinations
Packer/Manifold
UMP
P200U20-2RJ1, RJ2, RJ3
UMP200U20-2
Ump
rjpumps/fig5.eps
Packer/manifold
with piping
Kit
Discharge head
Alignment dowel
In
s
ert the po
s
itioning dowel
on the UMP in thi
s
hole
rjp
u
mp
s
\fig
3
6.ep
s
Connector'
s
o-ring
(-015 [0.551'' ID x
0.070'' wide])
Pigt
a
il fem
a
le connector/indexing t
ab
i
s
o
u
t
of it
s
s
ocket - thi
s
i
s
the incorrect po
s
ition
when
a
tt
a
ching the UMP!
Pigt
a
il fem
a
le connector/index-
ing t
ab
i
s
fitted in notch of it
s
s
ocket - thi
s
i
s
the correct
po
s
ition when
a
tt
a
ching the
UMP!