Red Jacket 344-001-5 Скачать руководство пользователя страница 2

Notice

Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose.

Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the
furnishing, performance, or use of this publication.

Veeder-Root reserves the right to change system options or features, or the information contained in this publication.

This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication
may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root.

Contact Red Jacket Technical Support for additional troubleshooting information at 800-323-1799.

DAMAGE GOODS/LOST EQUIPMENT

Thoroughly examine all components and units as soon as they are received. If any cartons are damaged or missing, write a
complete and detailed description of the damage or shortage on the face of the freight bill. The carrier's agent must verify the
inspection and sign the description. Refuse only the damaged product, not the entire shipment.

VR must be notified of any damages and/or shortages within 30 days of receipt of the shipment, as stated in our Terms and
Conditions.

VEEDER-ROOT’S PREFERRED CARRIER

1.

Fax Bill of Lading to V/R Customer Service at 800-234-5350.

2.

Call V/R Customer Service at 800-873-3313 with the specific part numbers and quantities that were received damaged or
lost.

3.

VR will file the claim with the carrier and replace the damaged/missing product at no charge to the customer. Customer
Service will work with production facility to have the replacement product shipped as soon as possible.

CUSTOMER’S PREFERRED CARRIER

1.

Customer files claim with carrier.

2.

Customer may submit a replacement purchase order. Customer Service will work with production facility to have the
replacement product shipped as soon as possible.

3.

If “lost” equipment is delivered at a later date and is not needed, VR will allow a Return to Stock without a restocking fee.

4.

VR will NOT be responsible for any compensation when a customer chooses their own carrier.

RETURN SHIPPING

For the parts return procedure, please follow the instructions in the “General Returned Goods Policy” pages of the “Policies and
Literature” section of the Veeder-Root North American Red Jacket Mechanical Products Price Book.   Veeder-Root will not accept
any return product without a Return Goods Authorization (RGA) number clearly printed on the outside of the package.

  

 Veeder-Root 2015. All rights reserved

.

Содержание 344-001-5

Страница 1: ...Installation Guide 4 AG Pump Service Kit Manual No A042 078 Revision E Part No 344 001 5...

Страница 2: ...f any damages and or shortages within 30 days of receipt of the shipment as stated in our Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Fax Bill of Lading to V R Customer Service at 800 234 5...

Страница 3: ...justing the Functional Element 9 To Adjust the Relief Pressure 9 Functional Element Parts List 11 Figures Figure 1 Electronic Line Leak Detector 4 Figure 2 Packer 4 Figure 3 Locating 7 Packer O Ring A...

Страница 4: ...ask someone who does WEAR EYE PROTECTION Wear eye protection when working with pressurized fuel lines or epoxy sealant to avoid possible eye injury WARNING This product operates in the highly combust...

Страница 5: ...Prevent Explosions and Fires Fuels and their vapors will explode or burn if ignited Spilled or leaking fuels cause vapors Even filling customer tanks will cause potentially dangerous vapors in the vic...

Страница 6: ...A OSHA regulations and federal state and local fire codes and other applicable local regulations The selection of any Veeder Root product must be based upon physical specifications and limitations and...

Страница 7: ...the pump close it 2 If an electronic line leak detection transducer is installed it must be removed from the leak detector port following instructions in the appropriate Line Leak installation manual...

Страница 8: ...ld remove the old quad seal from the base of the packer under the line leak port see Figure 3 9 Clean the seating surface and the sealing surface of the quad seal 10 Lubricate the quad seal with petro...

Страница 9: ...anifold Discharge Port 7 O Ring Packer Seal 7 O Ring Packer Seal Manifold Functional Element Functional Element Packer Packer Leak Detector Port Plug or Line Leak Detector Leak Detector Port Plug or L...

Страница 10: ...lb 40 61 N m NOTE suggested tools non sparking include a 3 4 wrench pipe wrench 1 4 Allen wrench 9 16 wrench screw driver wire cutter and wire stripper 20 If applicable open ball valve down line from...

Страница 11: ...gure 5 Functional Element 5 Carefully lift the functional element and remove it from the packer The old check valve and spring will be resting inside the packer NOTE The check valve and spring should...

Страница 12: ...s fully down the relief pressure is approximately 30 psi 207 kPa Fully up will result in relief pressures between 0 3 psi 0 20 kPa 3 Lubricate the cap s o ring with petroleum jelly and replace cap by...

Страница 13: ...with the dispenser furthest from the pump and work toward the pump 5 Pump start up is now complete Table 1 Approximate Pressures At Shut Off Pump Approximate Shut Off Pressure AGUMP33R1 UMP33R1 25 ps...

Страница 14: ...Casting 2 017 526 1 Diaphragm 3 066 883 1 Poppet 4 072 641 1 O Ring 41 64 x 5 64 5 076 421 3 Adjustment Screw 6 012 956 3 Cap 7 080 767 1 Spring 8 066 620 1 Plug 9 060 332 1 Seal 10 012 965 3 Top Cast...

Страница 15: ...For technical support sales or other assistance please visit www veeder com...

Отзывы: