Chapter 8. Monitoring
164
entitled to Monitoring, a
Probes
tab appears within its
System Details
page. This is where you will
conduct most probe-related work.
8.5.1. Managing Probes
To add a probe to a system, the system must be entitled to Monitoring. Further, you must have access
to the system itself, either as the system's root user, through the System Group Administrator role, or
as the Satellite Administrator. Then:
1. Log into the RHN website as either an Satellite Administrator or the System Group Administrator
for the system.
2. Navigate to the
System Details � Probes
tab and click
create new probe
.
3. On the
System Probe Creation
page, complete all required fields. First, select the Probe
Command Group. This alters the list of available probes and other fields and requirements. Refer
to
Appendix D, Probes
for the complete list of probes by command group. Remember that some
probes require the Red Hat Network Monitoring Daemon to be installed on the client system.
4. Select the desired Probe Command and the Monitoring Scout, typically
RHN Monitoring
Satellite
but possibly an RHN Proxy Server. Enter a brief but unique description for the probe.
5. Select the
Probe Notifications
checkbox to receive notifications when the probe changes state.
Use the
Probe Check Interval
dropdown menu to determine how often notifications should
be sent. Selecting
1 minute
(and the
Probe Notification
checkbox) means you will receive
notifications every minute the probe surpasses its CRITICAL or WARNING thresholds. Refer to
Section 8.4, “Notifications”
to find out how to create notification methods and acknowledge their
messages.
6. Use the
RHNMD User
and
RHNMD Port
fields, if they appear, to force the probe to communicate
via
sshd
, rather than the Red Hat Network Monitoring Daemon. Refer to
Section 8.2.3,
“Configuring SSH”
for details. Otherwise, accept the default values of
nocpulse
and
4545
,
respectively.
7. If the
Timeout
field appears, review the default value and adjust to meet your needs. Most but
not all timeouts result in an UNKNOWN state. If the probe's metrics are time-based, ensure the
timeout is not less than the time allotted to thresholds. Otherwise, the metrics serve no purpose,
as the probe will time out before any thresholds are crossed.
8. Use the remaining fields to establish the probe's alert thresholds, if applicable. These CRITICAL
and WARNING values determine at what point the probe has changed state. Refer to
Section 8.5.2, “Establishing Thresholds”
for best practices regarding these thresholds.
9. When finished, click
Create Probe
. Remember, you must commit your Monitoring configuration
change on the
Scout Config Push
page for this to take effect.
To delete a probe, navigate to its
Current State
page (by clicking the name of the probe from the
System Details � Probes
tab), and click
delete probe
. Finally, confirm the deletion.
8.5.2. Establishing Thresholds
Many of the probes offered by RHN contain alert thresholds that, when crossed, indicate a change
in state for the probe. For instance, the Linux::CPU Usage probe allows you to set CRITICAL and
WARNING thresholds for the percent of CPU used. If the monitored system reports 75 percent of its
Содержание NETWORK SATELLITE 5.3.0 - CHANNEL MANAGEMENT
Страница 1: ...Red Hat Network Satellite 5 3 0 Reference Guide Red Hat Network Satellite ...
Страница 32: ...20 ...
Страница 44: ...Chapter 4 Red Hat Update Agent 32 Figure 4 11 Available Package Updates ...
Страница 168: ...156 ...
Страница 180: ...168 ...
Страница 216: ...204 ...
Страница 232: ...220 ...
Страница 248: ...236 ...
Страница 260: ...248 ...
Страница 309: ...297 Appendix E Revision History Revision 1 0 Fri Feb 27 2009 ...
Страница 310: ...298 ...
Страница 318: ...306 ...