Abbreviations 

 

 

A  A 

Width of passage 

 

AKA 

Actuating contact „outside“ 

 

AKI 

Actuating contact „inside“ 

 AMP 

Lamp 

 

APA 

actuating switch for 

  

pharmacies 

 

APD 

Pushbutton for pharmacies 

 

APR 

locking bar for pharmacies 

 

APS 

safety device for pharmacies 

 

AS 

Connection or general 

  

schematic 

diagram 

 ATE 

Drive 

unit 

 ATM 

Drive 

module 

 

B BAT 

Battery-pack 

 BDE 

Control 

unit 

 

BDE-E 

Control unit electronic 

 

BDE-M 

Control unit mechanical 

 

BDE-R 

Control unit redundant 

 

BS 

BDE with lock 

 

C CAN-H 

Serial interface 

 CAN-L  Serial 

interface 

 

CO48 

special standard in France 

 CPU 

microprocessor 

 

D  D-STA 

Double sliding door drive 

 

DUO 

heavy door operator 

 

E EEPROM parameter 

storage 

 ELS 

Light 

barrier 

 EMK 

Receiver 

head 

 EPROM program 

storage 

 ES 

Electrical 

connection 

diagram 
 

E-STA 

Single sliding door drive 

 

E-STA-L  Single sliding door drive left 

 

E-STA-R  Single sliding door drive right 

 

F  F 

Length of header 

 

FEM 

Extended functions module 

 FIRST  redundant 

operator 

 

G  G 

Height of passage 

 GTR 

Gearbox 

 

H  HEA 

Manual unlocking „from 

outside“ 
 

HEI 

Manual unlocking „from 

inside“ 
 

HES 

Manual unlocking switch 

 

K KA 

Cable 

exit 

 

L LED 

Light-emitting 

diode 

 LS 

Wiring 

diagram 

 

M MOT 

Motor 

 

MP 

General installation plan 

 

N NET 

Power supply 

 

NSK 

Emergency fail close contact 

 
 
 

O OUT 

Output 

 

OVA 

Optical lock indicator 

 

R RAD-A 

Radar „outside“ 

 RAD-I 

Radar 

„inside“ 

 RED 

Redundant 

module 

 

S  SAA 

interlock control “exit 

  

actuation 

blocked” 

 SAG 

Control 

unit 

 S-AUS 

Interlock 

control 

 

SEA 

Interlock control “entrance 

  

actuation 

blocked” 

 SEK 

Transmitter 

head 

 

SHE 

Safety element, external 

 

SÖK 

Emergency opening contact 

 

SPS 

Stored program control SPC 

 SSA 

Slidebar 

operator 

 SSK 

Key-operated 

contact 

 

STA 

Sliding door drive 

 STD 

Socket 

 STG 

Control 

unit 

 STM 

Control 

module 

 STP 

Control 

p.c.b. 

 

SUR-A 

Time switch contact “exit 

  

mode” 

 

SUR-V 

Time switch contact “locking 

  

mode” 

 

T THS 

Thermostatic 

switch 

 TOS 

Break-out 

system 

 

TOZ 

Door hold-open time 

 

TSA 

Telescopic sliding door 

  

operator 

 TÜV 

Industrial 

inspectorate 

 

U UMR 

Guide pulley 

 μP 

Microprocessor 

 

V  VAK 

Lock indicating contact 

 VAL 

Locking 

alarm 

 VL 

Wiring 

list 

 VRR 

Locking 

device 

 

Z  ZLP 

Supplementary printed circuit 

  

board 

 

 

Содержание 5100 Series

Страница 1: ...ration mode Connect the FPC 902 to the black 4 conductor plug located on the left side of the Series 5100 control The following sequence of screens should occur Servicing the Series 5100 Sys 20 with the FPC 902 Hand Terminal Jan 2014 BG Press OK Press OK Press OK The screen sequences on the following pages start from this point and document the various adjustable parameters in the control When at ...

Страница 2: ...4 Bistable 5 MPV20 6 MPV16 7 Magnet 0 Without 3 Motor Powered Configure System Door Type Motor Lock Type Battery 20 3 Configure System Door Type Motor Lock Type Battery 20 0 3 If Lock on board will need set to 11 Fail Secure or 12 Fail Safe Press OK Configure System Door Type Motor Lock Type Battery 20 0 3 0 Battery 0 Without 1 Lead Set to 1 Lead if Lead Acid Battery onboard Press OK SERVICE STG Para...

Страница 3: ... 0 no creep section 1 2 5 of last travel 40 100 of travel Note As Creep Section is increased door speed is decreased Operation mode SERVICE STG Maintenance Functions Configure System Learning System Parameter PARAMETER Driving Cycle Time delay open Drive Entrance System Control unit Locking Close DRIVING CYCLE Ramp Seal Closing speed 20 Opening speed 36 Open Acceleration 30 Deceleration 30 Creep Se...

Страница 4: ...0 thru 20 are in 1 sec intervals 21 thru 40 are in 2 sec intervals providing 60 sec maximum delay SSK Delay 0 Reset with button 0 SSK Delay 0 Reset with button 0 Operation mode SERVICE STG Maintenance Functions Configure System Learning System Parameter PARAMETER Driving Cycle Time delay open Drive Entrance System Control unit Locking SSK Delay 0 TIME DELAY OPEN Time delay open 2 Time delay Rem Sw ...

Страница 5: ...me stack pressures change from 0 to higher number Motor Two Mot DRIVE Partial opening 20 Obstruction close 25 Obstruction open 25 Brake 0 Motor 6 Two Motors 0 Obstruction close 25 PARAMETER Driving Cycle Time delay open Drive Entrance System Control unit Locking DRIVE Partial opening 20 Obstruction close 25 Obstruction open 25 Brake 0 Motor 6 Two Motors 0 Obstruction open 25 If the door is reversi...

Страница 6: ...ttery charge monitor pcb 9 51 00167 must be installed in the door control Operation mode SERVICE STG Maintenance Functions Configure System Learning System Parameter PARAMETER Driving Cycle Time delay open Drive Entrance System Control Panel Locking ENTRANCE SYSTEM Door type 19 Measure A 0 Measure G 0 Door Leaf 0 Interlock 0 MEASURE A 0 Door Opening Width Measured in mm 650 2000 Default setting Onl...

Страница 7: ...ntenance Functions Configure System Learning System Parameter PARAMETER Driving Cycle Time delay open Drive Entrance System Control Panel Locking ENTRANCE SYSTEM Door type 19 Measure A 0 Measure G 0 Door Leaf 0 Interlock 0 ENTRANCE SYSTEM Door type 19 Measure A 0 Measure G 0 Door Leaf 0 Interlock 0 ENTRANCE SYSTEM Door type 20 Measure A 0 Measure G 0 Door Leaf 0 Interlock 0 DOOR TYPE 12 Flip Flow 1...

Страница 8: ...NGLISH 3 ENGLISH US PARAMETER Driving Cycle Time delay open Drive Entrance System Control panel Locking KEYBOARD 0 Locked Mode 1 OFF Mode Default op mode 0 DISPLAY PANEL Language 3 Keyboard 1 Contrast BDE1 20 Contrast BDE2 20 Brightness BDE1 20 Brightness BDE2 20 4 ESPANOL 5 NEDERLANDS CONTROL PANEL Mechanical Panel 3 Display panel Default op mode DISPLAY PANEL Language 3 Keyboard 1 Contrast BDE1 ...

Страница 9: ...Locking PARAMETER Driving Cycle Time delay open Drive Entrance System Control panel Locking CONTROL PANEL Mechanical Panel 3 Display panel Default op mode DISPLAY PANEL Language 3 Keyboard 1 Contrast BDE1 20 Contrast BDE2 20 Brightness BDE1 20 Brightness BDE2 20 BRIGHTNESS BDE1 20 CONTROL PANEL Mechanical Panel 3 Display panel Default op mode DISPLAY PANEL Language 3 Keyboard 1 Contrast BDE1 20 Co...

Страница 10: ...afe autolocks and door is to be locked when the door is Locked Also see Control Panel Display Panel Keyboard parameter PARAMETER Driving Cycle Time delay open Drive Entrance System Control unit Locking LOCKING Locking functions 2 Lock type Start Delay 0 Closed VRR Error 0 Closing Force 0 Start Delay 0 Delay time until door opens after unlocking 0 no delay 40 8 second delay Operation mode SERVICE S...

Страница 11: ...tem Learning System Parameter PARAMETER CAN BUS Input Output Miscellaneous Entrance System Control Panel Locking STG AUX0_OUT 0 ZLP AUX0_IN 0 AUX1_IN 0 AUX4_IN 0 Configurable Input Terminals 4 6 and 18 on STG Control Note With parameters identified as Safety a closed contact is required for normal door operation AUX0_OUT Dry contacts on STG to Terminals 8 NO 9 COM 10 NC Rated 1 Amp 30VDC ZLP1 Additi...

Страница 12: ...ut Miscellaneous Entrance System Control Panel Locking INPUT OUTPUT Ext Sw IN 0 Emerg Open Close 0 EMERG STOP Reset 0 SIO SIS SIA SIO Function SIO 2 Activate SIO 0 Suppression SIO 0 Activate SIO 0 Door position from which SIO Signal becomes active 0 active closed 1 inactive last 2 5 of opening 40 inactive entire opening width Operation mode SERVICE STG Maintenance Functions Configure System Learnin...

Страница 13: ...scellaneous Entrance System Control Panel Locking MISCELLANEOUS TOWA 1 Push to actuate open 0 Push to actuate close 0 Holding force 0 Lead time open 0 Lead time close 0 Push to actuate open 0 Disabled 0 Normal 0 Partial Default Disabled Normal If enabled will automatically open after pushed 3mm from closed position Partial Opens to reduced width Operation mode SERVICE STG Maintenance Functions Con...

Страница 14: ...ing delayed 8 sec The push to close function will interrupt the pre warning delay AUX00_OUT must be set to 9 Warning Operation mode SERVICE STG Maintenance Functions Configure System Learning System Parameter PARAMETER CAN BUS Input Output Miscellaneous Entrance System Control Panel Locking MISCELLANEOUS Alarm display Push to actuate open 0 Push to actuate close 0 Holding force 0 Lead time open 0 L...

Страница 15: ...aintenance Setup maintenance Cycles1000 Actual Reset Maintenance Are you sure Yes No The listed parameters in the center screen are for setting up a maintenance program for the unit and resetting it after target is met Operation mode SERVICE STG Functions Diagnostics Learning System Parameter Maintenance Maintenance Cycles1000 Target Weeks Actual Weeks Target Phone 800 438 1937 Cycles1000 Actual P...

Страница 16: ...arning ELS BAT emerg reaction Reset system Learning parameter For use when initially commissioning a door or significantly altering the mechanical characteristics of the door Learning parameter Are you sure Yes No Parameter Maintenance Functions Operation mode Diagnostics Operation mode SERVICE STG Diagnostics Learning System Parameter Maintenance Functions Cycles 123 Door parameters Peripheral dev...

Страница 17: ...nput Hours Door parameters Will illustrate active inputs SERVICE STG Learning System Parameter Maintenance Functions Operation mode Diagnostics DIAGNOSTICS Protocol Cycles Input Hours Door parameters Error history SERVICE STG Learning System Parameter Maintenance Functions Operation mode Diagnostics DIAGNOSTICS Error history Protocol Cycles Input Hours Door parameters List of current Errors and ab...

Страница 18: ... CAN nodes are searched Updates are searched STA20_UL Vx xx replace by STA20_UL Vx xx Yes No Updates are searched BDE D Vx xx replace by BDE D Vx xx Yes No The following sequence of screens are to be followed when updating door and display software Use the Down arrow to select Flash Programmer then press OK Press OK Use the Left arrow to select Yes then press OK Use the Left arrow to select Yes th...

Страница 19: ...update Manual update Indicate files Check files AKKU PASS FLASH PASS EEPROM PASS RTC PASS CAN PASS FPC902 Version 2 71 Nov 24 2013 10 48 48 FPC902 Service STG Service STG Slave Flash Programmer Setup FLASH PROGRAMMER Automatic update Manual update Indicate files Check files Lists the software stored on the SD card in the FPC902 Checks the software stored on the SD card in the FPC902 ...

Страница 20: ...SETUP Renew license Select language RENEW LICENSE Lapse counter 500 ID 3 076 305 230 KEY AKKU PASS FLASH PASS EEPROM PASS RTC PASS CAN PASS FPC902 Version 2 71 Nov 24 2013 10 48 48 FPC902 Service STG Service STG Slave Flash Programmer Setup SETUP Renew license Select language SELECT LANGUAGE DEUTSCH FRANCAIS ENGLISH ENGLISH US Not used in North America ...

Страница 21: ...f passage GTR Gearbox H HEA Manual unlocking from outside HEI Manual unlocking from inside HES Manual unlocking switch K KA Cable exit L LED Light emitting diode LS Wiring diagram M MOT Motor MP General installation plan N NET Power supply NSK Emergency fail close contact O OUT Output OVA Optical lock indicator R RAD A Radar outside RAD I Radar inside RED Redundant module S SAA interlock control e...

Отзывы: