Resistance measurement
1. Connect the red test wire to the VΩ terminal.
2. Connect the black test lead to the COM terminal.
3. Disconnect the measured circuit from power and discharge
all capacitors.
4. Set the rotary switch to position Ω.
5. Connect the test leads to the measured circuit.
6. The result will appear on the display.
Diode/continuity measurement
1. Connect the red test wire to the VΩ terminal.
2. Connect the black test lead to the COM terminal.
3. Set the rotary switch to diode/continuity position.
4. Connect the test leads to the measured circuit/diode.
CLEANING AND MAINTENANCE
• Clean the device with soft, slightly damp cloth, without
abrasive agents.
• To change the battery, unscrew the screw of the battery
compartment. Take out the battery compartment cover and
replace the battery (note the polarity). Close the battery
compartment cover and screw in the screw.
• The device will turn off after 15 minutes of idle.
SPECIFICATION
DC voltage
Range
Resolution
Accuracy
200 mV
0,1 mV
±(0,5% + 5)
2 V
1 mV
±(0,5% + 2)
20 V
10 mV
200 V
100 mV
600 V
1 V
±(1% + 5)