background image

Limited Warranty

CMT106 IDE controller utilityModule

14

Real Time Devices USA, Inc.

  Limited Warranty

Real Time Devices, Inc. warrants the hardware and software products it manufactures and
produces to be free from defects in materials and workmanship for one year following the date of
shipment from REAL TIME DEVICES. This warranty is limited to the original purchaser of
product and is not transferable.

During the one year warranty period, REAL TIME DEVICES will repair or replace, at its option,
any defective products or parts at no additional charge, provided that the product is returned,
shipping prepaid, to REAL TIME DEVICES. All replaced parts and products become the
property of REAL TIME DEVICES. Before returning any product for repair, customers are
required to contact the factory for an RMA number.

THIS LIMITED WARRANTY DOES NOT EXTEND TO ANY PRODUCTS WHICH HAVE
BEEN DAMAGED AS A RESULT OF ACCIDENT, MISUSE, ABUSE (such as: use of
incorrect input voltages, improper or insufficient ventilation, failure to follow the operating
instructions that are provided by REAL TIME DEVICES, "acts of God" or other contingencies
beyond the control of REAL TIME DEVICES), OR AS A RESULT OF SERVICE OR
MODIFICATION BY ANYONE OTHER THAN REAL TIME DEVICES. EXCEPT AS
EXPRESSLY SET FORTH ABOVE, NO OTHER WARRANTIES ARE EXPRESSED OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND REAL TIME
DEVICES EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED HEREIN. ALL
IMPLIED WARRANTIES, INCLUDING IMPLIED WARRANTIES FOR MECHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF
THIS WARRANTY. IN THE EVENT THE PRODUCT IS NOT FREE FROM DEFECTS AS
WARRANTED ABOVE, THE PURCHASER'S SOLE REMEDY SHALL BE REPAIR OR
REPLACEMENT AS PROVIDED ABOVE. UNDER NO CIRCUMSTANCES WILL REAL
TIME DEVICES BE LIABLE TO THE PURCHASER OR ANY USER FOR ANY DAMAGES,
INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EXPENSES, LOST
PROFITS, LOST SAVINGS, OR OTHER DAMAGES ARISING OUT OF THE USE OR
INABILITY TO USE THE PRODUCT.

SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL
OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS, AND SOME STATES
DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO
THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE
OTHER RIGHTS WHICH VARY FROM STATE TO STATE.

Содержание CMT106

Страница 1: ...CMT106 IDE Controller and Hard Drive Carrier utilityModule User s Manual Hardware Revision 1 0 Publication No CMT106 8 28 98...

Страница 2: ...ve Carrier utilityModule User s Manual REAL TIME DEVICES USA INC PO Box 906 200 Innovation Blvd State College PA 16804 0906 USA Phone 814 234 8087 FAX 814 234 5218 E Mail sales rtdusa com techsupport...

Страница 3: ...O Box 906 State College PA 16804 0906 USA Copyright 1998 by Real Time Devices USA Inc All rights reserved Printed in U S A PC XT PC AT are registered trademarks of IBM Corporation PC 104 is a registe...

Страница 4: ...PTER 3 INSTALLING THE UTILITYMODULE 5 Recommended Procedure 5 CHAPTER 4 CONNECTING THE UTILITYMODULE 7 PC 104 Bus Connectors CN1 and CN2 8 IDE CN3 9 CHAPTER 5 USING THE UTILITYMODULE 11 IDE Hard Disk...

Страница 5: ...ard PC 104 processor modules Features The following are major features of the CMT106 utilityModule Bus mode decodes IDE interface through the PC 104 bus for cableless operation Jumper selection of pri...

Страница 6: ...Features CMT106 IDE controller utilityModule 2 Real Time Devices USA Inc...

Страница 7: ...uring the utilityModule Jumpers Jumper JP1 configures the following functions Primary Secondary Jumper JP2 configures the following functions IRQ14 Primary IRQ15 Secondary Default Settings The utility...

Страница 8: ...Jumpers CMT106 IDE controller utilityModule 4 Real Time Devices USA Inc...

Страница 9: ...e on the PC 104 stack Touch a grounded metal part of the stack to discharge any buildup of static electricity Remove the utilityModule from its anti static bag Check that keying pins in the PC 104 bus...

Страница 10: ...Recommended Procedure CMT106 IDE controller utilityModule 6 Real Time Devices USA Inc...

Страница 11: ...ilk screened on the PC board It is also indicated by a square solder pad visible on the bottom of the PC board Please make certain you have correctly identified pin 1 of a connector before you connect...

Страница 12: ...standard for the PC 104 bus The following tables list the connector pinouts PC 104 XT Bus Connector CN1 Pin Row A Row B 1 IOCHCHK 0V 2 SD7 RESETDRV 3 SD6 5V 4 SD5 IRQ9 5 SD4 5V 6 SD3 DRQ2 7 SD2 12V 8...

Страница 13: ...sconnection of the PC 104 bus These keying pins are a part of the PC 104 standard and we strongly recommend you leave them in place If you have other modules without keying pins we suggest you modify...

Страница 14: ...round signal 20 n c 21 AEN Address Enable out 22 GND Ground signal 23 IOW I O Write out 24 GND Ground signal 25 IOR I O Read out 26 GND Ground signal 27 IOCHRDY I O Channel Ready in 28 BALE Bus Addres...

Страница 15: ...hard drive type NOTE If you are using this harddrive with an RTD CPU module enter 4095 for the number of cylinders Power Protection Circuitry To reduce the risk of damage due to power supply problems...

Страница 16: ...Power Protection Circuitry CMT106 IDE controller utilityModule 12 Real Time Devices USA Inc...

Страница 17: ...pplication What other devices were connected to the product How was power supplied to the product What features did and did not work What was being done when the product failed What were environmental...

Страница 18: ...s beyond the control of REAL TIME DEVICES OR AS A RESULT OF SERVICE OR MODIFICATION BY ANYONE OTHER THAN REAL TIME DEVICES EXCEPT AS EXPRESSLY SET FORTH ABOVE NO OTHER WARRANTIES ARE EXPRESSED OR IMPL...

Отзывы: