  IDE Hard Disk

The CMT106 provides an IDE interface to 2.5 inch, 2.1 Gbyte harddrive. This harddrive can be
set up as the primary or the secondary drive (you must be sure that your CPU bios supports both
primary and secondary drives). The CMT106 cannot be used as a slave drive.

Since the CMT106 provides the IDE decoding on-board, there is no need for any cabling. You
must be sure to disable any other IDE controllers that might be present on your CPU module or
VGA module.

You may need to run the setup program for your cpuModule or computer to configure the correct
hard drive type.

NOTE: If you are using this harddrive with an RTD CPU module, enter 4095
for the number of cylinders.

  Power Protection Circuitry

To reduce the risk of damage due to power-supply problems, the utilityModule includes several
protective components.

 

 

Module Power-Supply Protection

The utilityModule includes components to help prevent damage due to problems with the +5Vdc
power supply from the PC/104 bus or power-supply connector. Protection is provided for:

 

Over-current

 

Reversed polarity

 

Excessive voltage

This protection is only for the utilityModule, and will not protect other devices in a PC/104 stack .

The protective fuse is replaceable and is available from electronics suppliers. Its description and
part number are:

Littelfuse Nano

2

 SMF 1.0 amp, R451-001

Caution: 

Replace fuses only with parts of identical current and voltage rating.

User’s Manual

Содержание CMT106

Страница 1: ...CMT106 IDE Controller and Hard Drive Carrier utilityModule User s Manual Hardware Revision 1 0 Publication No CMT106 8 28 98...

Страница 2: ...ve Carrier utilityModule User s Manual REAL TIME DEVICES USA INC PO Box 906 200 Innovation Blvd State College PA 16804 0906 USA Phone 814 234 8087 FAX 814 234 5218 E Mail sales rtdusa com techsupport...

Страница 3: ...O Box 906 State College PA 16804 0906 USA Copyright 1998 by Real Time Devices USA Inc All rights reserved Printed in U S A PC XT PC AT are registered trademarks of IBM Corporation PC 104 is a registe...

Страница 4: ...PTER 3 INSTALLING THE UTILITYMODULE 5 Recommended Procedure 5 CHAPTER 4 CONNECTING THE UTILITYMODULE 7 PC 104 Bus Connectors CN1 and CN2 8 IDE CN3 9 CHAPTER 5 USING THE UTILITYMODULE 11 IDE Hard Disk...

Страница 5: ...ard PC 104 processor modules Features The following are major features of the CMT106 utilityModule Bus mode decodes IDE interface through the PC 104 bus for cableless operation Jumper selection of pri...

Страница 6: ...Features CMT106 IDE controller utilityModule 2 Real Time Devices USA Inc...

Страница 7: ...uring the utilityModule Jumpers Jumper JP1 configures the following functions Primary Secondary Jumper JP2 configures the following functions IRQ14 Primary IRQ15 Secondary Default Settings The utility...

Страница 8: ...Jumpers CMT106 IDE controller utilityModule 4 Real Time Devices USA Inc...

Страница 9: ...e on the PC 104 stack Touch a grounded metal part of the stack to discharge any buildup of static electricity Remove the utilityModule from its anti static bag Check that keying pins in the PC 104 bus...

Страница 10: ...Recommended Procedure CMT106 IDE controller utilityModule 6 Real Time Devices USA Inc...

Страница 11: ...ilk screened on the PC board It is also indicated by a square solder pad visible on the bottom of the PC board Please make certain you have correctly identified pin 1 of a connector before you connect...

Страница 12: ...standard for the PC 104 bus The following tables list the connector pinouts PC 104 XT Bus Connector CN1 Pin Row A Row B 1 IOCHCHK 0V 2 SD7 RESETDRV 3 SD6 5V 4 SD5 IRQ9 5 SD4 5V 6 SD3 DRQ2 7 SD2 12V 8...

Страница 13: ...sconnection of the PC 104 bus These keying pins are a part of the PC 104 standard and we strongly recommend you leave them in place If you have other modules without keying pins we suggest you modify...

Страница 14: ...round signal 20 n c 21 AEN Address Enable out 22 GND Ground signal 23 IOW I O Write out 24 GND Ground signal 25 IOR I O Read out 26 GND Ground signal 27 IOCHRDY I O Channel Ready in 28 BALE Bus Addres...

Страница 15: ...hard drive type NOTE If you are using this harddrive with an RTD CPU module enter 4095 for the number of cylinders Power Protection Circuitry To reduce the risk of damage due to power supply problems...

Страница 16: ...Power Protection Circuitry CMT106 IDE controller utilityModule 12 Real Time Devices USA Inc...

Страница 17: ...pplication What other devices were connected to the product How was power supplied to the product What features did and did not work What was being done when the product failed What were environmental...

Страница 18: ...s beyond the control of REAL TIME DEVICES OR AS A RESULT OF SERVICE OR MODIFICATION BY ANYONE OTHER THAN REAL TIME DEVICES EXCEPT AS EXPRESSLY SET FORTH ABOVE NO OTHER WARRANTIES ARE EXPRESSED OR IMPL...

Отзывы: