background image

CALIBRATION 

22 

 

6.2.4 

Weight Calibration Routine 

This continues from section 6.2.3. 

 

(i) 

Proportional Scaling Factor/Speed Compensation 

 

NOTE:   This  appears  only  if  dynamic  weighing  mode 

(“

dYn

”) is set, otherwise, skip to section 6.2.4 

(ii). 

“Proportional  Scaling”  compensates  for 
efficiency  losses  in  a  dynamic  lift,  and  is  a 
scaling  factor  based  on  the  maximum  load 
of  the  machine.  This  factor  is  more 
significant for large capacity machines. 

6. 

Press        again to confirm the entry in step 5.  
The screen displays “

LoAd FASt

”. 

7. 

Lift  the  FULL  bucket  through  the  weighing 
position  a  number  of  times  at  MAXIMUM 
speed,  each  time  noting  the  number 
displayed (the frequency signal from the load 
sensor).  

NOTE:  If  you  maintain  a  constant  lift  speed  and 

engine  revs  on  the  lifts,  the  frequency 
readings should not normally vary more than a 
few Hertz 

 

When an acceptable loaded, fast lift is made, 
press                to  confirm  the  entry.  The  screen 
then displays “

LoAd SLo

”.  

8. 

Lift  the  FULL  bucket  a  number  of  times  at  MINIMUM  speed,  each time noting 
the  number  displayed  (the  frequency  signal  from  the  load  sensor).  When  an 
acceptable slow lift is made, press        to confirm the entry. The screen then 
displays “

EmPt FASt

”.  

9. 

Lift the EMPTY bucket a number of times at MAXIMUM speed, each time noting 
the  number  displayed  (the  frequency  signal  from  the  load  sensor).  When  an 
acceptable  fast  lift  is  made,  press              to  confirm  the  entry.  The  screen  then 
displays “

EmPt Slo

”. 

10.

  Lift the EMPTY bucket a number of times at MINIMUM speed. Press the        to 

confirm,  as  before.  Speed  compensation  is  calculated  from  the  fast  and  slow 
lifts, and is automatically switched on. The screen then displays “

ZERO LIFt

”.

 

 

If you want to weigh 

dynamically, you need 

only perform this 

routine for Channel 1. 

Speed compensation 

and Proportional 

Scaling then takes 

effect for any other 

channel set for dynamic 

weighing (“dYn”). 

 

For channels 2 to 5, you 

subsequently perform a 

simple Zero and Cal 

Load lift regardless if 

the channel is set for 

dynamic weighing or for 

Static weighing. 

 

Содержание Weighlog 200

Страница 1: ...s product complies with Council Directive 2004 108 EC when installed and used in accordance with the relevant instructions Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unkn...

Страница 2: ...the Weighing Mode 9 3 3 Check Zero Weight 10 3 4 Zero Weight Set Tare 11 4 Weighing ______________________________________ 12 4 1 Dynamic Weighing 12 4 2 Static weighing 12 4 3 Trailer Weighing 13 4 4...

Страница 3: ...3 6 2 5 Overload Alarm Setup 24 6 3 CAL mode 2 25 6 3 1 Enter CAL Mode 2 25 6 3 2 Speed Compensation Channel 1 25 6 3 3 Live Static Channel 2 26 6 3 4 REF Button Channel 3 27 6 3 5 Time Date Channel 4...

Страница 4: ...ferent loader attachments different trailers or different commodities Each channel will display the net bucket weight lifted at any time If required the bucket weight can be added to the total for the...

Страница 5: ...on The instrument is calibrated independently for each channel 1 to 5 e g each channel can be dedicated to suit a particular attachment or commodity Channel 6 is used to programme the Overload Alarm C...

Страница 6: ...figured the channel total is automatically printed Or HOLD and power on to enter CAL Mode 1 ZERO BUCKET WEIGHT Press and hold for 3 beeps Press again to cancel Weigh empty bucket then press the REMOTE...

Страница 7: ...0 kg 20 400 20 400 lbs 102 0 102 000 102 000 kg 204 000 204 000 lbs MAX 9999 999 990 999 990 kg 999 990 999 990 lbs 2 2 Machine requirements The Weighlog translates pressure or strain to weight by mea...

Страница 8: ...re The correct lifting procedure is especially important for dynamic weighing The load should be lifted smoothly and consistently through the weighing position The best procedure is as follows 1 Havin...

Страница 9: ...dividual channel Separate channels are set up for either Static weighing or Dynamic weighing as part of the weight calibration routine 6 2 4 You then select the appropriate channel for the weighing mo...

Страница 10: ...ift the bucket through the reference position Two beeps will be heard The display will show a value 2 b Static weighing mode Lift the bucket up to the reference position and stop A single beep will be...

Страница 11: ...le alarm will beep THREE times and the display will flash 0 00 4 a Dynamic weighing mode Lift the bucket through the reference position Two beeps will be heard The display will show a value 4 b Static...

Страница 12: ...nstead of a calculated weight you have lifted too slowly or too quickly for speed compensation to work Try again or recalibrate over a more suitable lift speed range 6 2 4 4 2 Static weighing Static w...

Страница 13: ...sed NOTE Always sample the trailer weight with the tipper body raised to the same position at which weight calibration was performed Sampling at a different position will adversely affect weighing acc...

Страница 14: ...E g If the Weighlog reading is 10 high then reduce the cal factor by 10 The actual calibration factor can also be determined by a simple calculation using the true weight and the displayed weight as f...

Страница 15: ...s the button to print the total weight that has been recorded to that channel since it was last reset If the printer mode is set to REC a short Job Record will be printed Fig 13 If the printer total i...

Страница 16: ...r example after completing a load The job number increments by one each time any channel total is reset ENT Print Mode If ENT print mode is set in CAL Mode 3 the instrument will automatically print th...

Страница 17: ...utton or the Remote Enter button for 5 seconds The display will flash 5 times and then go to zero If REC or ROLL print mode is enabled the instrument will automatically generate a printout 5 2 Display...

Страница 18: ...utton to cycle the digit from 0 to 9 or to move the decimal point 1 000 1 100 1 200 1 300 1 400 3 Release the button and the next digit will flash 4 Repeat steps 1 2 and 3 as necessary to change the o...

Страница 19: ...orm the following calibration steps for each channel to be calibrated Refer to the appropriate sections for additional information NOTE 2 A full bucket must be used so that the software can calculate...

Страница 20: ...STAT MODE Load FASt Fast lift full load Load Slo Slow lift full load Empt FASt Fast lift empty bucket note 1 p 18 Empt Slo Slow lift empty bucket ZERO LIFT Sets Prop Scaling Speed ZERO LIFT Comp for a...

Страница 21: ...in to display the weight calibration factor CALF Fig 19 Default Factor 1 000 Set the initial calibration factor to equal the lift capacity of the machine e g if the lift capacity is 1 5 tonnes then se...

Страница 22: ...The screen then displays LoAd SLo 8 Lift the FULL bucket a number of times at MINIMUM speed each time noting the number displayed the frequency signal from the load sensor When an acceptable slow lif...

Страница 23: ...NOTE If you are loading bags of known weight ensure they are evenly distributed in the bucket or on the pallet Also see note 1 page 18 14 Programme the known weight section 6 1 and press to confirm Th...

Страница 24: ...ple Empty lift 3100Hz noted when doing the weight calibration routine ref 6 2 4 Cal Factor 1 000 Alarm Load 2000kg Threshold Hz 3100 2000 x 1 000 5100Hz Programme the appropriate figure in the normal...

Страница 25: ...ough the settings Speed Compensation is switched on automatically after weight calibration in dynamic weighing mode The factors are displayed here ON OFF Press to toggle FASt xxxx milliseconds Weight...

Страница 26: ...is a larger error e g 50 60kg If with an empty bucket the weight reading is lower at a slower lift speed than at a fast speed then reduce the factor by 2 3 until the error is removed FrEq xxxx Hertz F...

Страница 27: ...fitted AUTO Ref Dir sensor can be used in conjunction with REF button to take a weight measurement Press to toggle 6 3 5 Time Date Channel 4 The display alternates between Hr Mn and 00 00 1 Programme...

Страница 28: ...units are tons tonnes Press to toggle When tons units is selected the test load weight is entered in tons tonnes A number of 1 000 denotes 1ton tonne When kgs or lbs units is selected the test load w...

Страница 29: ...Automatic printing ref section 4 4 Fig 13 ROLL Automatic printing ref section 4 4 Fig 14 ENT Automatic printing after each bucket weight is entered OFF No automatic printing after clearing the last lo...

Страница 30: ...he button and the text stops scrolling The first 4 characters are displayed with the first character flashing The display will resume scrolling after 15 seconds if no other button is pressed 2 Enter e...

Страница 31: ...load sensor lead If the wiring is OK then contact your local RDS distributor Error Message CAL Err If the Autocal routine is not fully completed i e the Zero lift and the LOAD lift the display will fl...

Страница 32: ...CALIBRATION 32 Channel Attachment Trailer Commodity Weighing Mode Cal Factor 1 2 3 4 5...

Страница 33: ...ld the REF outer left button on power up to access the Diagnostics mode On entry the screen will display diag for 1 second followed by a display of the live frequency from the pressure sensor The 3 ch...

Страница 34: ...e Section 2 1 p 7 units Section 3 3 p 10 units para 2b delete a second beep is heard and Section 3 4 p 11 units para 4b delete a second beep is heard and Section 4 4 p 14 add and weighing is not possi...

Отзывы: