ATHENE 100
– SPREADER RATE CONTROLLER
20
9.3
The “Quantity in Hopper” display
If the Hopper Maximum Quantity is set to a value above zero in the
calibration mode (refer to the Installation/Calibration Manual to set this), the
display will
count down from the maximum figure
, showing the quantity of
product remaining in the hopper.
When the calculated weight reaches the pre-programmed hopper alarm-
weight, the instrument will alarm in the same manner as described above.
9.3.1 Set Alarm Quantity
1. Select the channel then press and
hold the button for 5 seconds
The current alarm quantity appears (fig
8a). The factory default setting is 500kg
(0500).
2. Continue holding the button.
3. PRESS and RELEASE the button to
select the digit or decimal point to
change, or...
4. HOLD the button to change the digit
or move the decimal point.
Remember, setting a decimal point sets
the units as tonnes. If no decimal point is
set, the units are in kgs.
5. Release the button to return to the
normal operating mode.
9.3.2 Resetting the “Hopper Maximum Quantity” figure
Select the channel, then press and hold the button. The instrument
will give 10 beeps then resets to the default figure.
The factory default setting is 2000kg.
Figure 8a: View Alarm Quantity
Press and Hold
Figure 8b: Set Alarm Quantity
3
4
HOLD