![RD RDC6585PC Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/rd/rdc6585pc/rdc6585pc_manual_1424383071.webp)
RDC6585PC Control System manual
V1.0
SHENZHEN RUIDA TECHNOLOGY
62
control algorithm will be changed a little when other types are selected.
Feeding Mode
: it has single-way mode and two-way mode for option. If it is of
single-way feeding, it is unnecessary to check the coordinates. Feeding can be conducted in the
single-way mode; if it is of two-way feeding, the system will check the maximum and minimum
coordinates. The odd sequence means feeding should be done to one direction and the even
sequence means feeding done to the other direction. The initial direction for the first time can
be changed through setting the directional polarity or modifying the plus and minus values of
the feeding length.
Power-Off-Restart Delay
: it can be set to be 0~3000ms. After the power-off of the
electricity grid, the power supply of the system will not drop to 0 at once. There is a delay
during this time. The delay value set here should basically consistent with the actual off-delay
value. If the deviation of set value is larger, on the de-energizing for continuous engraving,
either the figure processed for the second time is not closed with that before the cutoff, or it is
coincided with that too much.
Press Control
: if the machine has a pole to press the material on Y axes, then select
press control, and, users can select the Y axis
’
home position based on machine.
Y-axis double driver
: if machine has two Y-motor driver, then enable Y-axis double
driver.
Mirror cutting
: if machine has two X-motor, and they work back-to-back to cut some
mirror graph, then select the mirror cutting function.
After the configuration parameters in the manufacturer parameters, such as
directional polarity, control mode, laser type and laser PWM frequency, are
modified, the system should be reset. Such a modification can function upon
the resetting of the system.
Enable parameters
Door Opening Protection
: If this item is enabled, then the door opening protection
must be connected to the controller, or, the machine will not run.
Whether to enable the blower
: If using wind out port to control the blower by the
graph layer parameter, this item must be enabled, or, the wind output is a signal for other using.
Multi-head auto layout parameters
Head distance N
: This is the distance between the two X axis when they all return to
Prompt