Cobra-Tac User's Guide
P/N 956-6000-00 (May 2004)
page 47
b. Grasp the cable close to the connector. Your thumb should rest against
the edge of the Cobra-Tac
.
c. Pull the cable straight out away from the connector with a gentle side-
to-side rocking motion. Do not apply any upward force on the connec-
tor as it is being disconnected.
The cable should be connected with a straight inward motion only. Use the
following procedure to connect the cable.
a. Apply a light coat of DC-111 lubricant to the rubber portion of the end-
cap connector pins. This will help seat the connector.
b. Gently push the cable straight in toward the end-cap connector. Do not
apply any upward force on the connector as it is being connected.
c. Roll the retaining strap over the connector.
CAUTION.
When disconnecting or connecting the Cobra-Tac
I/O cable,
do not apply any upward force on the connector as it is being pulled on/off.
Applying an upward angle as the cable is connected/disconnected puts
stress on the connector. This may cause several serious problems: a)
The connector or connector pins can crack. b) The O-ring on the bottom of
the connector can be damaged. c) The molded urethane on the connector
may separate from the brass insert.
If the connector is damaged in any
of these ways, your Cobra-Tac
will flood.