When the lock cylinder is fitted, you
must compensate for the thickness of
the cover (17 mm) with a suitable
cylinder extender.
Fit the lock cylinder and extender to
the lock housing.
4.12
Before the cylinder ring can be fitted,
the correct length screws must be
defined:
A
First insert the tension plate into the
cylinder hole. Then insert the
screws to be used through the
tension plate and lock housing and
screw them in so that they go into
the cylinder ring.
B
Pull out the cylinder ring so that the
screws touch the bottom against the
tension plate.
C
Measure distance ‘A’.
D
Remove the screws.
E
Cut the screws to measurement
‘A’ + 2 mm.
F
Replace the screws and tighten
them.