4. Button Functions
4a. Home
4b. Save Job (Hold for 3s)
4c. Advanced MIG Settings Menu
4d. Load Job (Hold for 3s)
DC Spot
Setting
Values
Description
Pre-flow
0-20s
Set how long you would like your gas to flow before the arc ignites.
Peak Amp
10-200A
Set the peak welding current.
Down Slope
0-20s
Set how long it takes for the Peak Amp to reach the End Amp.
End Amp
10-200A
Set the End Amp to adjust how hot your weld will finish.
Post Flow
0-20s
Set how long you would like your gas to flow after the arc ends.
Spot Time
0-10s
Set the length of time to run the SPOT function.
ArcPlus™
0-50A
ArcPlus keeps the volt amps constant by adjusting the welding current proportionally as the arc voltage
increases or decreases during a weld. It helps give better puddle control when weaving, reduced heat input
and increased side wall fusion.
AC Spot
Setting
Values
Description
Pre-flow
0-20s
Set how long you would like your gas to flow before the arc ignites.
Peak Amp
10-200A
Set the peak welding current.
Down Slope
0-20s
Set how long it takes for the Peak Amp to reach the End Amp.
End Amp
10-200A
Set the End Amp to adjust how hot your weld will finish.
Post Flow
0-20s
Set how long you would like your gas to flow after the arc ends.
Balance
±5
Adjust the AC Balance up to 5% above or below the calculated value.
AC Frequency
50-250Hz
Adjust the frequency of the AC waveform.
Spot Time
0-10s
Set the length of time to run the SPOT function.
Diameter
1.0, 1.6, 2.0, 2.4, 3.2, 4.0
Optimises the welding arc ignition in AC TIG based on the chosen tungsten diameter.
DC HCT
Setting
Values
Description
Pre-flow
0-20s
Set how long you would like your gas to flow before the arc ignites.
Start Amp
10-200A
Set the starting current when the arc ignites.
Up Slope
0-20s
Set how long it takes for the Start Amp to reach the Peak Amp.
Peak Amp
10-200A
Set the peak welding current.
HC Base Amp
10-200A
Set the Base Amp for the Heat Control Trigger.
Down Slope
0-20s
Set how long it takes for the Peak Amp to reach the End Amp.
End Amp
10-200A
Set the End Amp to adjust how hot your weld will finish.
Post Flow
0-20s
Set how long you would like your gas to flow after the arc ends.
AC HCT
Setting
Values
Description
Pre-flow
0-20s
Set how long you would like your gas to flow before the arc ignites.
Start Amp
10-200A
Set the starting current when the arc ignites.
Up Slope
0-20s
Set how long it takes for the Start Amp to reach the Peak Amp.
Peak Amp
10-200A
Set the peak welding current.
HC Base Amp
10-200A
Set the Base Amp for the Heat Control Trigger.
Down Slope
0-20s
Set how long it takes for the Peak Amp to reach the End Amp.
End Amp
10-200A
Set the End Amp to adjust how hot your weld will finish.
Post Flow
0-20s
Set how long you would like your gas to flow after the arc ends.
Balance
±5
Adjust the AC Balance up to 5% above or below the calculated value.
AC Frequency
50-250Hz
Adjust the frequency of the AC waveform.
Diameter
1.0, 1.6, 2.0, 2.4, 3.2, 4.0
Optimises the welding arc ignition in AC TIG based on the chosen tungsten diameter.
DIGITAL SCREEN - TIG
19
Содержание Xcel-Arc MULTI 230 AC/DC
Страница 2: ...2 ...
Страница 71: ...NOTES 71 ...