2T/4T/SPOT
Setting
Values
Description
Pre Flow
0-20s
Set how long you would like your gas to flow before the arc ignites.
Slow Feed
0-10
Set the amount of Creep Start to allow for smoother arc ignition when welding at higher welding speeds.
Welding Amp
Set the peak welding current.
Burn Back
0-10
Set how far the wire will burn back once the torch trigger has been released.
Post Flow
0-20s
Set how long you would like your gas to flow after the arc ends.
Spot Timer
0.5 - 25s
Set the length of time to run the SPOT function.
S2T
Setting
Values
Description
Pre Flow
0-20s
Set how long you would like your gas to flow before the arc ignites.
Slow Feed
0-10
Set the amount of Creep Start to allow for smoother arc ignition when welding at higher welding speeds.
Start Amp %
1-200%
Set the Start Amp % to adjust how hot your weld will start.
Start Amp Time
0-20s
Set how long the Start Amp will run.
Welding Amp
Set the peak welding current.
Burn Back
0-10
Set how far the wire will burn back once the torch trigger has been released.
Post Flow
0-20s
Set how long you would like your gas to flow after the arc ends.
S4T
Setting
Values
Description
Pre Flow
0-20s
Set how long you would like your gas to flow before the arc ignites.
Slow Feed
0-10
Set the amount of Creep Start to allow for smoother arc ignition when welding at higher welding speeds.
Start Amp %
1-200%
Set the Start Amp % to adjust how hot your weld will start.
Welding Amp
Set the peak welding current.
End Amp %
1-200%
Set the End Amp % to adjust how hot your weld will finish.
Burn Back
0-10
Set how far the wire will burn back once the torch trigger has been released.
Post Flow
0-20s
Set how long you would like your gas to flow after the arc ends.
3. Advanced MIG Settings
4. Button Functions
4a. Home
4b. Save Job (Hold for 3s)
4c. Advanced MIG Settings Menu
4d. Load Job (Hold for 3s)
DIGITAL SCREEN - MIG SMART-SET
16
Содержание Xcel-Arc MULTI 230 AC/DC
Страница 2: ...2 ...