Page 22
·Incorrect cutting air pressure
·Serious wear and tear on parts
·Ensure that the working air
pressure range is 0.35-0.55MPa
·Replace with new consumables
9.2. Alarm and solutions
Error
code
Category
Possible cause
Countermeasure
E10
Overcurrent
protection
Continuously
output the
maximum
capacity current
of machine
Restart the machine. If it is still in overcurrent
protection, contact after-sales service.
E32
Overvoltage
protection
Input grid
voltage is too
high
Turn it off and on again. If the alarm cannot be
eliminated and the grid voltage remains too
high, check the power grid voltage and wait for
the grid to be normal before welding. If the grid
voltage is normal and the alarm persists,
contact professional maintenance personnel.
E60
Overheating
Inverter IGBT
temperature is
too high
Do not
turn off the machine. Wait for a while,
and then continue welding after the
indicator goes out.
E61
Overheating
Output rectifier
diode
temperature is
too high
Do not
turn off the machine. Wait for a while,
and then continue welding after the
indicator goes out.
NOTE!
After applying the above countermeasures, the alarm still persists or reappears.
Please contact professional maintenance personnel.
9. Packaging, transportation, storage and waste disposal
10.1. Transportation requirements
In the process of handling the equipment, it should be handled with care, and should not be
dropped or severely impacted. Avoid moisture and rain during transportation.