background image

37

g

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

• Disconnect electric power to the washer before servicing.

• Never start the washer with any guards/panels removed.

• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the washer is properly grounded.

W003

37989

24. DRIVE PULLEY AND HELIX

a. Remove outer tub assembly from washer,

paragraph 23.

b. Remove cap screw, washer and helix holding

drive pulley to input shaft of transmission
assembly, 

Figure 42.

c. Lift drive pulley up and out from between tub

support legs.

NOTE: When reinstalling pulley, place a small
amount of No. 03200P Lubricant to top side of
drive pulley that will be contacting flat washers.
Lubricate helix ramps and bore with a small
amount of No. 03200P Lubricant. See 

Figure 43.

IMPORTANT: 

DO NOT OVER LUBRICATE!

Excess lubricant can be thrown into pivot dome
area during normal operation of washer. Any
lubricant on pivot dome or isolator will cause
premature tripping of the out-of-balance switch.
This condition will persist until lubricant is
removed.

Figure 42

W271SE3A

WASHER

DRIVE

PULLEY

CAP SCREW

HELIX

Содержание ec2011wa3059

Страница 1: ...Commercial Automatic Washers CE Approved Metered and Nonmetered Models See Page 2 for Model Numbers Commercial Laundry Technical Publications P O Box 990 Ripon WI 54971 0990 SERVICE Part No 37989 11 96 ...

Страница 2: ...al injury or property damage which may result The manufacturer will not be responsible for any injury or property damage arising from improper service and or service procedures W009 Recognize Safety Symbols Words and Labels a DANGER Immediate hazards which WILL result in serious injury or death a WARNING Hazards or unsafe practices which COULD result in serious injury or death a CAUTION Hazards or...

Страница 3: ...erly grounded W003 37989 Nameplate Location IMPORTANT When writing for information on any washer be sure to mention model and serial number Model and serial number will be found on nameplate as shown Model Identification Information in this manual is applicable to these washer models Model Number Nonmetered Model Metered Model Electronic Control Model One Speed Motor Two Speed Motor EC2011WA3059 X...

Страница 4: ...t of Cabinet 6 4 Wire Harness to Motor 6 SECTION II Service Procedures 5 Control Panel Assembly 7 6 Timer Assembly 10 7 Meter or Timer Case Assembly 12 8 Drain Hose Elbow 13 9 Loading Door 13 10 Front Panel 15 11 Motor and Mounting Bracket 15 12 Idler Lever and Pulley 17 13 Motor Drive Pulley 18 14 Motor Switch 21 15 Agitator 22 16 Cabinet Top Assembly 22 17 Cabinet Top Assembly Removal 23 18 Agit...

Страница 5: ...SECTION IV Service Helps 35 No Hot Water 51 36 No Cold Water 51 37 No Warm Water 52 38 Water Fill Does Not Stop at Proper Level 52 39 Timer Does Not Advance 53 40 Motor Does Not Run 54 41 No Agitation 54 42 Constant Agitation 55 43 Washer Smokes Overheats Cycles on Motor Thermal Overload Protector Switch Actuator Kicks In and Out 55 44 Slow Spin or No Spin 56 45 Constant Spin 56 46 Washer Stops in...

Страница 6: ... the washer before servicing Never start the washer with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the washer is properly grounded W003 NOTE Have a qualified electrician check polarity of wall receptacle If a voltage reading is measured other than that illustrated the qualified electrician should correct the p...

Страница 7: ...d Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the washer is properly grounded W003 37989 4 WIRE HARNESS TO MOTOR Figure 4 Figure 4 Figure 3 WIRE HARNESS CONNECTION BLOCK W329SE3A EARTH Ground WIRES 3 CONTROL HOOD WIRE HARNESS TO TOP LEFT REAR CORNER GUSSET OF CABINET Figure 3 CORNER GUSSET W340SE1A EARTH Ground WIRES EARTH Ground SCREW ...

Страница 8: ...efore servicing Never start the washer with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the washer is properly grounded W003 IMPORTANT When reference is made to directions right or left in this manual it is from the operator s position facing the front of the washer Figure 5 5 CONTROL PANEL ASSEMBLY a CONTROL PA...

Страница 9: ...S Unbalanced Load In Use Rinse or Spin Figure 6 1 Remove two control panel attaching screws and lay assembly forward on protective pad on cabinet top 2 Disconnect wires from light NOTE Refer to wiring diagram when rewiring light 3 Squeeze locking tabs together and pull light out rear of control panel d PRESSURE SWITCH Figure 6 1 Remove two control panel attaching screws and lay assembly forward on...

Страница 10: ...re 7 NOTE Lockwashers must be between switches and control panel when installing switches Figure 7 4 Disconnect wires from switches and indicator lights NOTE Refer to appropriate wiring diagram when rewiring switches and indicator lights 5 Remove control panel overlay by peeling it from control panel frame NOTE Control panel overlay has an adhesive backing f CONTROL PANEL OVERLAY Installation NOTE...

Страница 11: ...ng in movable locking tabs located on each side of terminal block plug Figure 9 Then pull terminal block plug away from timer 5 Disconnect earth ground wire from terminal on timer Figure 9 IMPORTANT To avoid an open circuit DO NOT pull on terminal block wires when removing block from timer as this could damage wires or terminal crimpings Before attaching wire harness terminal blocks to timer make ...

Страница 12: ...ear of coin vault in meter case Figure 8 6 While holding timer bracket up against rear of coin vault install cap screw and tighten firmly Figure 8 7 Make sure wire harness is routed along bottom of meter case so it will not interfere with any moving parts in meter case SETSCREW W238SE1A CLUTCH Figure 10 c TIMER REMOVAL Nonmetered Models 1 Loosen two setscrews holding timer knob to timer shaft Figu...

Страница 13: ... When installing meter case shoulder screw must be installed in outer hole Figure 8 to enable timer bracket to slide under screw head 7 Remove front panel paragraph 10 8 Remove carriage bolts and locknuts holding meter case to cabinet top 9 Carefully remove meter case and gasket from cabinet top b TIMER CASE REMOVAL Nonmetered Models 1 Remove timer from timer case paragraph 6 step c 2 Remove two c...

Страница 14: ... from inner hose NOTE When installing elbow on inner hose DO NOT allow hose inside of washer to twist Direct elbow toward drain receptacle and secure elbow to washer cabinet 9 LOADING DOOR a Open loading door Figure 14 b Remove two screws holding left hinge to door and remove gasket if present and hinge Figure 14 c With loading door raised to vertical position swing left side of door toward front ...

Страница 15: ...efore servicing Never start the washer with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the washer is properly grounded W003 37989 DOOR FRONT W288SE3A Procedure Two Procedure One Procedure Three DOOR FRONT W289SE3A DOOR FRONT W290SE3A Figure 15 ...

Страница 16: ...off or drained to prevent water spillage c Loosen hose clamps and remove hoses from pump assembly Figure 17 d Unhook idler spring from clip on front of motor mounting bracket Figure 17 IMPORTANT Use care when releasing idler lever tension If idler spring is overstretched washer operation will be affected 10 FRONT PANEL Figure 16 a Remove two screws from bottom edge of front panel b Pull bottom of ...

Страница 17: ...r washer operation a Clean any corrosion or foreign material from motor shaft that will be contacting the double D slot in pump impeller b Apply a thin film of No 03637P Lubricant to end and sides of motor shaft This lubricant helps keep moisture out of the hub area and retards corrosion c Align pump impeller hub with motor shaft Make sure belt encircles rear pump leg carefully push pump onto moto...

Страница 18: ...ht film of No 03637P Lubricant to area of idler lever that makes contact with motor mounting bracket IMPORTANT DO NOT OVER LUBRICATE Excess lubricant can be thrown into pivot dome area during normal washer operation Any lubricant on pivot dome or snubber pad and isolator assembly will cause premature tripping of the out of balance switch This condition will persist until lubricant is removed 12 ID...

Страница 19: ...e removing hoses from pump hoses must be pinched off or drained to prevent water spillage c Loosen hose clamps and remove hoses from pump assembly Figure 18 d Unhook idler spring fromidler lever Figure 20 IMPORTANT Use care when removing idler spring If idler spring is overstretched washer operation will be affected e Reach in and around right side of motor and run belt off right side of large dri...

Страница 20: ...d Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the washer is properly grounded W003 37989 Figure 19 MOTOR ASSEMBLY MOTOR EMBOSSES MOTOR EMBOSS MOTOR SHAFT Clean shaft and apply a thin film of lubricant No 03637P W272SE3A REAR PUMP LEG Must be located between belt when installing pump assembly PUMP ASSEMBLY PUMP LEGS PUMP MOUNTING SCREWS ...

Страница 21: ...s must be reconnected to ensure that the washer is properly grounded W003 37989 Figure 20 W249PE3D RETAINER RING WASHER Nylatron WASHER Felt IDLER PULLEY SCREW PUMP ASSEMBLY BELT Agitate and Spin 50 Hertz IDLER SHAFT CLIP WASHER LOCKNUT RUBBER MOTOR MOUNT Upper SCREW SHOULDER BOLT WASHER IDLER LEVER SPRING SCREW IDLER LEVER LOCKNUT MOTOR MOUNTING BRACKET WASHER SPACER ROLL PIN MOTOR PULLEY MOTOR S...

Страница 22: ... screws from bottom edge of front panel Figure 16 b Pull bottom of panel away from washer until hold down clips located on top flange of panel disengage from slots in cabinet top c Remove two screws holding motor shield to motor Figure 20 and remove shield d Disconnect wire harness from motor switch by pressing down on locking tab on top of connection block and at the same time pull connection blo...

Страница 23: ...ty If hooks are placed between vanes damage to agitator may occur c Using a rocking motion back and forth carefully lift agitator off drive bell 16 CABINET TOP ASSEMBLY a Remove front panel paragraph 10 b METERED MODELS 1 Remove timer assembly paragraph 6 step a 2 Remove shoulder screw and cap screw from inside meter case 3 Remove two cabinet top hold down screws 4 Remove security bolt if present ...

Страница 24: ...osed e Open cabinet top assembly paragraph 16 f Lift front of cabinet top slightly and pull forward to disengage from rear hold down brackets g Pull top forward far enough to permit disconnecting earth ground wires from top rear corner gusset of washer cabinet Figure 33 disconnect wires from mixing valve solenoids at rear of washer NOTE Refer to appropriate wiring diagram when rewiring mixing valv...

Страница 25: ... WING NUTS W298SE1A Figure 25 L021IE1A BOLT INDENT JAWS JAW LIP LARGE NUT WING NUT Figure 24 NOTE Drive Bell Tool No 253P4 must be updated with jaws No 294P4A and Bolt No 294P4B to remove the 36443P Drive Bell Kit c Back bolt out of 294P4 Drive Bell Tool approximately one third of the way Figure 24 d Place tool over drive bell making sure indent on jaws line up with side slots on drive bell Figure...

Страница 26: ...off lower seal bead 3 Grasping bottom of seal pull straight up freeing upper seal bead W293SE1A TURN ADJUSTABLE WRENCH COUNTERCLOCKWISE TO REMOVE DRIVE BELL W294SE1A HUB SHOULDER HUB ASSEMBLY HEX NUT TRANSMISSION OUTPUT SHAFT WASHER BRONZE BEARING Figure 27 k Thoroughly clean all foreign material from seal mounting area of hub assembly bronze bearing and washer Figure 27 l Lubricate new seal with ...

Страница 27: ...ole in top of drive bell and into transmission shaft NOTE Tighten new shoulder screw to approximately 60 to 80 inch pounds 6 86 to 9 15 N m f Place new plug over hole in drive bell and firmly press into place using palm of your hand NOTE It may be necessary to insert the end of a paper clip along side of plug as it is pressed into drive bell to release entrapped air IMPORTANT When fully seated plu...

Страница 28: ...wrench remove screws holding switch to switch holder Figure 31 e Remove switch and screws from switch holder f Insert screws into holes in new switch g Place a thin piece of metal or paper in front of switch to keep screws from falling through holes in switch holder h Place switch assembly into switch holder Figure 31 i Tighten screws using an open end wrench and torque to 10 inch pounds 1 14 N m ...

Страница 29: ...h 16 b Remove two screws holding mixing valve to mounting bracket at rear of washer cabinet Figure 33 NOTE When installing mixing valve tab on bottom flange must be placed in positioning hole in mounting bracket c Pull mixing valve out toward front of washer far enough to permit disconnecting water inlet and fill hoses from mixing valve Figure 33 d Remove wires and quick disconnect blocks from mix...

Страница 30: ...filler hose from outer tub cover Figure 34 NOTE When installing filler hose white line on hose must be aligned with line located on top side of outer tub cover Figure 34 d There are eight tub cover hold down tabs which snap over the outer tub flange Using special tub cover tool Part No 273P4 insert two prongs of tool underneath each side of tandem tabs Figure 34 Tilt tool toward center of tub cove...

Страница 31: ...ern until tub cover is fully seated Visually check each tab area again to ensure cover is seated IMPORTANT When installing outer tub cover always use a new cover gasket NOTE Clean and remove any foreign material in gasket groove of outer tub cover and outer tub flange e Lay gasket into gasket groove of tub cover Figure 35 f Using your fingers press gasket down into gasket groove of tub cover Avoid...

Страница 32: ...oved during servicing these ground wires must be reconnected to ensure that the washer is properly grounded W003 37989 OUTER TUB W255SE3A OUTER TUB COVER OUTER TUB COVER GASKET TUB FLANGE PLACE FINGERS UNDER THIS AREA AND PULL OUT AND AWAY FROM TUB AND AT THE SAME TIME LIFT UP ON TUB COVER TO REMOVE COVER OFF TUB FLANGE OUTER TUB COVER OUTER TUB TUB COVER CLIP AREA 8 POSITIONING TAB Viewed from un...

Страница 33: ...es approximatelyhalf way around tub before clothes guard can be removed n CLOTHES GUARD INSTALLATION Place clothes guard on top of washtub making sure clothes guard pins line up with holes in washtub Then carefully push clothes guard down into washtub until all pins snap into their respective holes k Remove four screws and washers holding washtub to hub Figure 37 l Lift washtub and clothes guard o...

Страница 34: ... tub seal and hold in this position during the next three steps TO INSTALL NO 495P3A HUB AND SEAL KIT NOTE The No 27615P Sealant 3M800 is not supplied in the kit a Thoroughly clean all foreign material from inner surface of outer tub flange IMPORTANT All foreign material must be removed from inner surface of outer tub flange before installing No 495P3A Hub and Seal Kit Figure 38 b Apply a small am...

Страница 35: ...ot available place No 237P4 Hex Wrench over large hex nut then tap hex wrench with a hammer until hub assembly turns or until large hex nut will no longer tighten l To install No 27125 washtub gasket follow these steps 1 Thoroughly clean all foreign material from seal surface area of hub and bronze bearing 2 Apply a small amount of nonstaining petroleum jelly such as Vaseline to both surfaces wher...

Страница 36: ...NT Before setting washtub into place make sure holes in hub assembly are aligned with holes in gasket n Secure washtub to hub assembly using four cap screws and four gaskets from 27202P Screw and Gasket Kit supplied in kit o Install supplied outer tub cover gasket and outer tub cover paragraph 21 IMPORTANT When installing outer tub cover always use a new outer tub cover gasket p Install drive bell...

Страница 37: ... each support leg to outer tub Figure 41 Then lift transmission balance ring and pivot dome off tub NOTE To prevent porcelain damage leg plates must be installed on outside of outer tub flange when reinstalling support legs Do not overtighten screws as this could cause stripping or porcelain damage Tighten screws between 90 and 130 inch pounds 10 3 to 14 87 N m j Turn outer tub upright and remove ...

Страница 38: ...ve pulley to input shaft of transmission assembly Figure 42 c Lift drive pulley up and out from between tub support legs NOTE When reinstalling pulley place a small amount of No 03200P Lubricant to top side of drive pulley that will be contacting flat washers Lubricate helix ramps and bore with a small amount of No 03200P Lubricant See Figure 43 IMPORTANT DO NOT OVER LUBRICATE Excess lubricant can...

Страница 39: ...e ground wires must be reconnected to ensure that the washer is properly grounded W003 37989 Figure 43 BEARING BEARING HOUSING ASSEMBLY Lower BRAKE ASSEMBLY BRAKE SPRING Through Serial No 9606029040 WASHER Thick WASHER Thin HELIX WASHER CAP SCREW PIVOT DOME WASHER BASE W183SE3A BRAKE PAD RUBBER SLEEVE SHOULDER SCREW SUPPORT LEG DRIVE PULLEY APPLY NO 03200P LUBRICANT HERE SNUBBER PAD AND ISOLATOR A...

Страница 40: ...ging brake pads If problems occur with steps 3 or 4 remove brake assembly and correct problem 25 BRAKE ASSEMBLY a Remove drive pulley and helix from outer tub paragraph 24 b Remove two flat washers from transmission shaft Figure 43 IMPORTANT Two large flat washers must be in place between brake spring and drive pulley when reassembling Thicker washer must contact top side of drive pulley See Figur...

Страница 41: ... housing from outer tub paragraph 26 NOTE It may be necessary to tap lightly on bearing housing to loosen it from transmission tube IMPORTANT When installing lower bearing housing pivot dome and brake assembly apply No 27604P Anti Seize Compound to area of transmission tube that will be contacting bearing Figure 44 To prevent porcelain damage leg plates must be installed on outer tub flange when r...

Страница 42: ... these ground wires must be reconnected to ensure that the washer is properly grounded W003 37989 Figure 44 BALANCE RING W185SE3A RACK AREA OF TRANSMISSION TRANSMISSION ASSEMBLY MARKED SIDE OF BALANCE RING APPLY NO 27604P ANTI SEIZE COMPOUND TO THIS AREA OF BOTH UPPER AND LOWER TRANSMISSION TUBES CENTER OF RACK NOTE If there is no mark on balance ring before disassembly mark it and also note the p...

Страница 43: ...ide back and forth f Position slide in slot on rack NOTE Put a light film of transmission oil in slot on rack also transmission case where internal gear will ride TRANSMISSION DISASSEMBLY Refer to Figure 45 for assembly sequence a Place transmission in a vise with input shaft end up Clamp only the case not the shaft NOTE Supporting transmission in this manner will allow oil to collect in transmiss...

Страница 44: ...smission assembly from vise q Apply anti seize compound No 27604P to smooth area of both transmission tubes that will be contacting upper and lower bearings Figure 44 g Place internal gear into transmission case Make sure guide pin on internal gear fits in hole on slide IMPORTANT Never install a used internal gear in a new transmission case If transmission case and internal gear are to be reused b...

Страница 45: ...onnected to ensure that the washer is properly grounded W003 37989 Figure 45 W186SE3A INTERNAL GEAR SPECIAL SCREW LOCKWASHER WASHER DRIVE PINION SHAFT Input SCREW WASHER REDUCTION GEAR DOWEL PIN Through Serial No 9604069377 CAP SCREW DOWEL PIN Through Serial No 9604069377 TRANSMISSION COVER ASSEMBLY SLIDE RACK AGITATOR PINION TRANSMISSION CASE ASSEMBLY WASHER SHAFT Output RETAINER RING TRANSMISSIO...

Страница 46: ... on transmission assembly Figure 44 29 UPPER BEARING ASSEMBLY a Remove transmission assembly paragraph 27 b Remove screws holding each support leg to outer tub Figure 41 c Lift complete pivot dome with drive pulley brake assembly lower bearing housing transmission assembly and balance ring attached off outer tub IMPORTANT To prevent porcelain damage leg plates must be installed on outer tub flange...

Страница 47: ...ubber pad and isolator assembly or pivot dome Any lubricant on pivot dome or isolator will cause premature tripping of the out of balance switch b Clean surface of pivot dome Then carefully place tub module back into washer making sure pivot dome is positioned properly in dome recess of washer base Figure 47 NOTE Make sure the word FRONT on outer tub is facing toward front of washer c Use No 289P4...

Страница 48: ...ing these ground wires must be reconnected to ensure that the washer is properly grounded W003 37989 j Reinstall cabinet top k Remove control panel reconnect pressure hose to pressure switch Then reinstall control panel l Reinstall washer front panel m Reconnect washer power cord and open water supply valves NOTE Washer must be run through a complete cycle to make sure it is operating properly PRE...

Страница 49: ...veling legs d Washer must not rock After washer is at desired height tighten locknuts securely against bottom of washer base If these locknuts are not tight washer will not remain stationary during operation e Install rear extension leg kit No 566P3 optional equipment at extra cost to raise height of washer NOTE Washer should be installed on a reasonably firm floor Flexing of a weak floor may caus...

Страница 50: ...esents approximately one inch 25 4 mm increase or decrease of water level in washtub IMPORTANT DO NOT turn adjusting screw more than 3 4 of a turn in either direction as switch may be damaged and flooding could result Figure 50 W261SE1A ADJUSTING SCREW OUT OF BALANCE SWITCH ASSEMBLY W277SE1A ACTUATOR ARM LEVER Figure 52 33 OUT OF BALANCE SWITCH a Raise cabinet top assembly paragraph 16 b Check for...

Страница 51: ...incorrect wiring Refer to appropriate wiring diagram SECTION IV Service Helps gWARNING To reduce the risk of electric shock fire explosion serious injury or death Disconnect electric power to the washer before servicing Never start the washer with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the washer is properl...

Страница 52: ...re binding in complete valve armature guide Broken weak or missing mixing valve armature Disassembly valve and replace spring or replace spring complete valve A siphoning action started in washer will cause water Install No 562P3 Siphon Break Kit Provide an to be siphoned from washer during cycle due to air gap around drain hose and drain receptacle end of drain hose being lower than cabinet top o...

Страница 53: ...ing diagram and reattach wire Broken loose or incorrect wiring Refer to appropriate wiring diagram Timer is designed to pause when going from agitate Allow time for timer to go through that step See to spin diagram for information on time required Timer is designed to stop if an out of balance load Open lid and automatically reset out of balance has been encountered while washing clothes load swit...

Страница 54: ...verload protector has cycled Wait two or three minutes for overload protector to reset If protector cycles repeatedly refer to paragraph 43 Bind in upper or lower motor bearing Remove belt and determine if motor shaft will spin Replace motor if shaft is locked up Broken loose or incorrect wiring Refer to appropriate wiring diagram Power cord is miswired Refer to appropriate wiring diagram for corr...

Страница 55: ...ssembly POSSIBLE CAUSE TO CORRECT Belt is tacky and does not allow proper slip Check belt and replace if defective Belt tension is too great and does not allow Make sure idler spring is properly connected proper slip Inoperative timer Test timer and replace if inoperative Motor switch functions inoperative Check motor switch and replace if inoperative Bind in water pump Replace pump Brake pads bin...

Страница 56: ...T OF BALANCE switch Rearrange load in washtub Motor will not run Check motor and replace if inoperative Sheared motor pulley roll pin Remove drive motor and replace roll pin and any other damaged parts Motor overload protector has cycled Wait two or three minutes for overload protector to reset If protector cycles repeatedly refer to paragraph 43 No clearance or stuck brake pads Free sticky brake ...

Страница 57: ...t timer and replace if inoperative Broken loose or incorrect wiring Refer to appropriate wiring diagram Motor overload protector has cycled Wait two or three minutes for overload protector to reset If protector cycles repeatedly refer to paragraph 43 Motor switch functions inoperative Check motor switch and replace if inoperative Brake transmission or motor have locked Check that all these compone...

Страница 58: ...entering spring s Connect or replace centering spring s Washer is not properly leveled Adjust leveling legs Washer is installed on weak spongy carpeted Relocate washer or support floor to eliminate weak or or built up floor spongy condition Incorrect or loose cabinet screws Replace with correct screws or tighten Base damaged washer was dropped Replace base assembly Balance ring not positioned prop...

Страница 59: ...ELICATE CYCLE X INDICATOR LIGHT GLOWS FUNCTION IN USE LIGHT RINSE LIGHT SPIN LIGHT WATER TEMP CYCLE MOTOR SPEED TIME Min Sec W A S H WASH FILL OR AGITATE X H W C N FAST PP FAST D SLOW 10 33 PAUSE X 05 S P I N SPIN X X N FAST PP SLOW D SLOW 1 56 SPIN AND SPRAY X X COLD N FAST PP SLOW D SLOW 31 SPIN X X N FAST PP SLOW D SLOW 36 SPIN AND SPRAY X X COLD N FAST PP SLOW D SLOW 07 SPIN X X N FAST PP SLOW...

Страница 60: ...RMANENT PRESS CYCLE D DELICATE CYCLE X INDICATOR LIGHT GLOWS FUNCTION IN USE LIGHT RINSE LIGHT SPIN LIGHT WATER TEMP CYCLE MOTOR SPEED EATON TIME Min Sec W A S H Coin Slide Starting Stroke 17 82 Mallory 16 84 Eaton X H W C N FAST PP FAST D SLOW 57 AGITATE OR VARIABLE FILL X H W C N FAST PP FAST D SLOW 7 00 PAUSE X 21 S P I N SPIN X N FAST PP SLOW D SLOW 1 25 SPIN AND SPRAY X COLD N FAST PP SLOW D ...

Страница 61: ...CLE PP PERMANENT PRESS CYCLE D DELICATE CYCLE X INDICATOR LIGHT GLOWS FUNCTION IN USE LIGHT RINSE LIGHT SPIN LIGHT WATER TEMP CYCLE MOTOR SPEED TIME Min Sec W A S H Coin Slide Starting Stroke 16 84 Eaton X H W C N FAST PP FAST D SLOW 1 23 AGITATE OR VARIABLE FILL X H W C N FAST PP FAST D SLOW 10 00 PAUSE X 34 S P I N SPIN X N FAST PP SLOW D SLOW 1 32 SPIN AND SPRAY X COLD N FAST PP SLOW D SLOW 30 ...

Страница 62: ...VI Internal Wiring of Washer Motor Switch gWARNING To reduce the risk of electric shock fire explosion serious injury or death Disconnect electric power to the washer before servicing Never start the washer with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the washer is properly grounded W003 AUX RED WHITE RUN ST...

Страница 63: ...nels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the washer is properly grounded W003 37989 Motor Assembly 2 Speed Motors W311SE3B WIRE HARNESS CONNECTION BLOCK WHITE BROWN BLUE YELLOW VIOLET RED R P Y BU BR W AUX RED WHITE G Y BU BR W R 4P M YELLOW BROWN BLUE VIOLET YELLOW 6P M OVERLOAD PROTECTOR P RUN START W224SE3A ...

Страница 64: ...injury or death Disconnect electric power to the washer before servicing Never start the washer with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the washer is properly grounded W003 37989 ...

Отзывы: