10
g
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the washer before servicing.
Never start the washer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
37989
Figure 9
Figure 8
6. TIMER ASSEMBLY
a. TIMER REMOVAL (Metered Models):
NOTE: DO NOT attempt to repair timer.
1. Unlock and remove meter case service
door.
2. Remove timer bracket cap screw,
Figure 8.
3. Slide timer bracket left to disengage
bracket from shoulder screw. Lift timer and
bracket up and out of meter case through
service door opening as far as wires will
permit.
NOTE: If only replacing clutch, proceed to step 7.
4. Disengage wire harness terminal block plug
from timer by pressing in movable locking
tabs (located on each side of terminal block
plug),
Figure 9. Then pull terminal block
plug away from timer.
5. Disconnect earth (ground) wire from
terminal on timer,
Figure 9.
IMPORTANT: To avoid an open circuit, DO NOT
pull on terminal block wires when removing block
from timer as this could damage wires or terminal
crimpings. Before attaching wire harness terminal
blocks to timer, make sure all male terminals on
timer are straight and are capable of accepting
terminals from wire harness terminal blocks.
IMPORTANT: Be careful not to dislodge or
damage two timer motor lead wires while handling
timer.
NOTE: To avoid timer damage, do not allow timer
to be struck on corners, edges of frame or on
timer shaft.
6. Remove two screws holding timer to timer
bracket,
Figure 9.
7. Loosen setscrew holding clutch to timer
shaft,
Figure 10.
TIMER
BRACKET
METER
CASE
W334SE1A
METER
CASE
CAP
SCREW
TIMER
SHOULDER
SCREW
TIMER
BRACKET
ATTACHING
SCREWS
W237SE1A
TERMINAL
BLOCK PLUG
GROUND WIRE
TERMINAL
LOCKING
TABS
GROUND
WIRE
TIMER