3-17
3.6
Serial Interface
The serial interface is designed for communication with CAM in accordance with
IEC 61162-1/-2 and IEC 61924-2 and / or for communication with an Integrated
Navigation System (INS) for remote control functionality.
CAUTION
After a disconnection of interfaces, it takes up to 30 seconds until the
correct values are displayed again.
CAUTION
It is possible to configure the serial interface as Alert & Remote
communication at the same time. But to ensure the correct repetition
rates it is recommended to use the interface only for Alert or Remote
communication!
The following telegrams can be used for receiving data:
Interface
Possible Telegrams
Repetition Rate
Acknowledge Alarm
ACK
Only once to
acknowledge an alert
Alert Command
ACN
Only once to
acknowledge an alert
Date/Time for the Alerts
ZDA
1
1 s (recommended)
All headings and
selected sources
PANZHDS
Only once if the
selected source should
be changed
Heading difference alert
thresholds
PANZDAT
Only once if the
threshold should be
changed
1
The ZDA telegram is optional. The Distribution Unit is also able to transmit the
information to the Operation Units via CAN-Bus.