Install and Operation
19
Rev. B 06/2011
CM
5.2
Mechanical Installation
All sensors come with a 1.0 m (3.3 ft) cable or 3.0 m (9.8 ft) and 2 mounting
nuts. You can mount the sensor in brackets or cutouts of your own design, or
you can use the mounting bracket accessories.
Figure 4: Sensor with fixed mounting bracket
5.3
Cable
The color code of the cable and 6 conductors are shown in the following table
:
8
Outer
Jacket
1
Power
+
2
Power -**
3
RxD
4
TxD/
Alarm
5
TC+/
mV+
6
TC-/
mV-
7
Shield
J
brown
orange
black
blue
violet
white
red
K
yellow
yellow
red
0 to 5 V
grey
yellow
brown
** Die RS232’s Ground must be connected to Power-
Table 1: Sensor Wiring Color Code