16
Illuminator Security & ATC Modes Detail :
Enter this mode by a long 4 second press of LHS button to turn LHS LED
Flashing RED.
Pressing the LHS button again momentarily will turn the LHS LED Flashing
GREEN. A third momentary press will turn the LHS LED Flashing
AMBER. Momentarily pressing the button a fourth time will cause the
LHS led to flash in a Red-Green-Amber sequence.
Each of these responses indicates which setting mode you are in.
A further momentary press of LHS Button will exit from the mode entry,
both LEDs will go blank for 1 second and then return to the standard
indication of either operating mode or programming mode (depending
on which mode the illuminator was in previously before selecting manual
controls)
The following modes are available :
Illuminator Reset Mode (LHS LED : Flashing RED)
RHS LED: Solid RED
Keep RHS BUTTON depressed for 4 seconds. RHS LED stays solid RED and
then after 4 seconds both LEDs flash AMBER to show the illuminator has
been reset. This operation is equivalent to the factory reset button on the
remote control. It will not re-set a PIN if one is present.
Remote Control Disable and Enter Operating Mode or Remote Control
Enable and enter Programming Mode (LHS LED : Flashing GREEN)
RHS LED:
Enable Remote: Solid GREEN
Disable Remote: Solid RED
Note : If there is a PIN present and the Illuminator is in Operating mode
you cannot enable the Remote Control and enter Programming Mode
Enable & Disable of Manual Control Buttons (LED A : Flashing AMBER)
RHS LED:
Enable Manual Button Control
–
Solid GREEN
Disable Manual Button Control
–
Solid RED
Note : If the illuminator is in Operating Mode and the buttons are
currently disabled, you cannot re-enable.