13
Manual buttons can be accessed by removing the base cover of the
illuminator
The buttons are active in both programming mode and operating mode
regardless of whether a PIN is present or not unless you have previously
disabled the manual buttons
As soon as manual button mode is entered by pressing the Left Hand
Button, the standard LED indicators will be disabled and will indicate a
new set of information, Standard LED indicators are enabled after exiting
manual button modes.
Note : Unless detailed as part of the functionality, if an invalid or
blocked button push is attempted, both LEDs will flash Red
Mode Selection by using LHS Button :
A momentary press of LHS button turn LHS LED solid RED and enters the
user into the
Illuminator Settings Modes
.
In these modes you can change the following settings :
-
Power Level
-
Photocell sensitivity
-
Indicator LED status (On or Off)
A continuous 4 second press of the LHS button turns LHS LED flashing RED
and enters the user into the
Illuminator Security Modes
.
In these modes you can change the following Security/Configurations :
-
Illuminator Re-set
-
Disable Remote Control and enter Operating Mode or Enable
Remote Control and enter Programming Mode
-
Manual Button Enable / Disable
-
ATC Enable / Disable
*Note
–
If the status indicator LEDs are disabled and you use the manual
buttons the indicator LEDs will still illuminate accordingly