5
Step 2.
Mounting Illuminator
VARIO2 Extreme is delivered as standard with bracket at the bottom of
the unit. This can be moved to the top of the unit if required. See page
18 for optional brackets
Step 3.
Connect to low voltage power supply (24V AC or DC)
Note :
Red = Positive ; Black = Negative
Installers can extend or reduce supply cable length using appropriately rated
cable and connector box.
Step 4.
Telemetry Input (Orange & Purple)
As default the telemetry input will be wired together so that the unit turns
on/off automatically via the photocell. If required to be activated by PIR
or alarm system, connect to appropriate, volt-free or Digital input (5V
max). Volt free input/dry contact: Non polarity sensitive, short circuit =
light on
Digital input: Orange = Digital +5v, Purple = Signal GND
0V = Light on, 3V = Light off
Warning :
When controlling the lamps by a digital input the absolute
maximum voltage on the telemetry line is 5V DC.
Care must be taken that the connection is the correct polarity.
The signal ground must not be connected to the lamp power input.
The illuminator may be damaged if not connected as described
above.
Step 5.
Photocell following output (White & Yellow)
Volt free output - normally open (day) to normally closed (night).
Connect direct to camera if required to control switchover of day/night
cameras.
Step 6.
Program using optional VARIO Remote Control (VRC) or the
manual control buttons.
Step 7.
Set PIN (If Required) (Can only be done with the optional VARIO
Remote Control(VRC)