29
Enable Ethernet Messages
GTm
Where:
m
=
0
to disable Ethernet messages
m
=
1
to enable Ethernet messages
When Ethernet messages are enabled, any error reports are sent to the
most recent UDP or TCP address from which a command has been
received.
Messages are of the form:
Evt1,e
Where:
e
= event value: 32 to 47 are lighting error codes.
Clear any Errors
GR
If Ethernet messages are not enabled, the last event or error number can be
read by this command. If there was a lighting error, the VTR4 resumes
normal operation.
The reply is in the same form as the
GT
command above. If there are no
outstanding events or errors, then only the prompt
>
is returned.
Set/Clear the Webpage Password
EY
EY asc1, asc2, asc3, asc4, asc5, asc6
This command sets the password required to access the webpages. If
EY
is entered on its own, then the password is cleared. There are six optional
parameters, which are decimal ASCII values for a password from one to
six letters. A value of
65 is ‘A’, 66 is ‘B’, and
so on to 90 is
‘Z’.
Report internal temperatures
AT
Each of the two internal LED PCBs has a temperature sensor, and the AT
command reports a string with the following format:
TM 18C 19C [=19C] [.21C19C] 50C 70C [100%]