background image

9

PRV

XPAK FT

BOILER

BALL

VALVE

SYSTEM

PUMP

(S3)

SYSTEM

SENSOR

BALL

VALVE

CHECK

VALVE

T&P

GAUGE

UNION

IN

LE

T

O

UT

LE

T

UNION

UNION

MIXING

VALVE

PRV

BALL

VALVE

BALL

VALVE

PRESSURE

REDUCING VALVE

BOILER

PUMP

EXPANSION

TANK

DHW

PUMP

DRAIN

AIR

SEPARATOR

PRESSURE

GAUGE

BALL

VALVE

UNION

BALL

VALVE

DRAIN

TO

BOILER

COLD

INLET

HOT

OUTLET

FROM

SYSTEM

12” MAX APART

MIX

OUTLET

MAKE UP

WATER

TO

SYSTEM

COLD

INLET

(S5) IND

TANK

SENSOR

FROM

BOILER

INDIRECT

FIRED

STORAGE

WATER

HEATER

DRAIN

DRAIN

Fig. 3: VERSA MODE 2

Figure 3 depicts connecting the indirect water heater to

the system loop. This diagram also shows the optional

anti-scalding mixing valve (may be required in some ju-

risdictions).  The  boiler  shown  in  this  diagram  is  the

XPak FT. Other boilers may be used instead.

Содержание RSIT115

Страница 1: ...not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas s...

Страница 2: ...2 Rev 1 Changes to New Additions New Deletions None...

Страница 3: ...cation 8 Boiler and Circulator Sizing 8 Temperature Pressure Relief Valve 8 Plumbing 8 Controls 11 START UP 13 Purging the System 13 Flushing the System 13 Checking Circulator 13 Set the Thermostat to...

Страница 4: ...es not answer please contact your local Raypak representative or visit our website at www raypak com Keep this manual with the water heater after installation Local plumbing and electrical codes must...

Страница 5: ...will be re placed in kind only per Raypak s standard warranties Scalding Water Temperature Setting DANGER Safety and energy conservation are factors to be considered when selecting the water temperatu...

Страница 6: ...cial Products 5th ed b The pressure of the heat transfer medium must be limited to a maximum of thirty 30 psig 207kPa by an approved safety or relief valve Freeze Protection The water heater and water...

Страница 7: ...al L First Hour Rating gal hr L hr Continuous Draw Rating gal hr L hr Standby Loss F hr C hr Minimum Boiler Ouptut BTUH kw Coil Length ft m Heating Surface Area Sq ft m2 Heating Coil Flow GPM L min Co...

Страница 8: ...ing should terminate in a safe location This discharge piping must comply with local and national plumbing codes The piping must be rated for 120 F and 150 PSI Plumbing A tempering valve may be requir...

Страница 9: ...BALL VALVE DRAIN TO BOILER COLD INLET HOT OUTLET FROM SYSTEM 12 MAX APART MIX OUTLET MAKE UP WATER TO SYSTEM COLD INLET S5 IND TANK SENSOR FROM BOILER INDIRECT FIRED STORAGE WATER HEATER DRAIN DRAIN F...

Страница 10: ...VALVE T P GAUGE UNION INLET OUTLET UNION UNION MIXING VALVE BALL VALVE PRV BALL VALVE S6 IND SUPPLY SENSOR BOILER PUMP EXPANSION TANK DHW PUMP DRAIN CHECK VALVE PRESSURE GAUGE BALL VALVE UNION BALL V...

Страница 11: ...SA control is pre configured to handle an indirect storage water heater The VERSA control can also be configured to give priority to the domestic hot water or to space heating To connect the unit to a...

Страница 12: ...r always remember that in principle an indirect water heater operates as another heating zone The difference is that when the indirect water heater calls for heat the indirect water heater cir culator...

Страница 13: ...ugh the tank to change the water vol ume at least two times Checking Circulator Check that the circulator or zone valve operates when there is a call for heat When a call for heat is initiated water s...

Страница 14: ...g Replace zone valve Circulator pump not working Check power supply Replace circulator Tank thermostat Thermostat set too low Check thermostat wiring Scale build up Check coil for scale build up Desca...

Страница 15: ...15 Below is a list of the replacement parts for the Stainless Steel Indirect Water Heater IPL diagram showing replacement parts 2 M 1 M 3 M PARTS...

Страница 16: ...lfunctions or failures resulting from failure to install the indirect water heater in accordance with applicable building codes ordinances or good plumbing and electrical trade practices c Damages mal...

Страница 17: ...tion for an in warranty indirect water heater replacement you must provide Raypak with at Raypak s option either the indirect water heater replaced in warranty with the original rating label and all t...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20 www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A...

Отзывы: