background image

16

!"#$#%&'!()**)+%,!

-./!*012034!560789:;;!56::9!#8<7/:=6!(06:/!>:06:/;!08<!56./0?:!%083;

!

@&+&*)"

!

Raypak Inc. (Raypak) warrants this indirect water heater to be free from defects in materials and workmanship, under normal use and service, for the appropriate 
applicable Warranty periods. At its option, Raypak will repair or replace a malfunctioning indirect water heater in accordance with the terms of this Limited 
Warranty, if it fails in normal use and service during the appropriate applicable Warranty periods. The replacement indirect water heater must be supplied by 
Raypak. The replacement indirect water heater unit, will be warranted only for the unexpired portion of the original unit’s appropriate applicable Warranty period.

!

&--&A%#B&!')%&

!

The effective Date of warranty coverage (or the beginning of the applicable Warranty periods) is the date of installation of the water heater if properly 
documented. Otherwise, it is the date of manufacture of the water heater plus ninety (90) days.

 

)CC"#A)D"&!()**)+%,!C&*#E'5

!

The applicable Warranty periods will vary depending on the ownership and/or use (or water heating application) of the unit as follows: 
LIFETIME RESIDENTIAL LIMITED WARRANTY COVERAGE – as long as the indirect water heater is installed in a single family dwelling owned by its original 
owner/end user, Raypak will furnish a replacement unit (if the tank leaks) provided the unit has not been moved from the original installation site or been 
rendered inoperable by an event listed in the Warranty exclusions section of this Limited Warranty. This warranty coverage applies only to the original indirect 
water heater purchased and installed at each site. It does not apply to any in-warranty replacement indirect water heater. The owner/end user must be able to 
provide proof that he or she purchased the indirect unit in order to qualify for Lifetime Residential Limited Warranty coverage. 

10 YEAR RESIDENTIAL LIMITED WARRANTY COVERAGE – if the indirect water heater is installed in a single family dwelling owned by persons other than the 
original owner/end user, the applicable Warranty periods are ten (10) years from the effective Date for the tank provided the unit has not been moved from the 
original installation site or rendered inoperable by an event listed in the Warranty exclusions section of this Limited Warranty. This warranty coverage applies only 
to the original indirect water heater purchased and installed at each site. It does not apply to any in-warranty replacement indirect water heater. 

5 YEAR COMMERCIAL LIMITED WARRANTY COVERAGE – if the indirect water heater is installed in a multiple family dwelling or any other type of commercial 
business, the applicable Warranty periods are five (5) years from the effective Date for the tank provided the unit has not been moved from the original 
installation site or rendered inoperable by an event listed in the Warranty exclusions section of this Limited Warranty. This warranty coverage applies only to the 
original indirect water heater purchased and installed at each site. It does not apply to any in-warranty replacement indirect water heater.

  

 

()**)+%,!&FA"G5#E+5

!

This Limited Warranty will not cover:  
a) Service trips to the installation site to teach you how to install, use, or maintain this indirect water heater or to bring the indirect water heater’s installation into 
compliance with local building codes and regulations. 
b) Damages, malfunctions, or failures resulting from failure to install the indirect water heater in accordance with applicable building codes/ordinances or good 
plumbing and electrical trade practices. 
c) Damages, malfunctions, or failures resulting from improper installation or failure to operate and/or maintain the indirect water heater in accordance with the 
manufacturer’s instructions provided. 
d) Performance problems caused by improper sizing of the boiler and/or the indirect water heater. 
e) Chloride content >250ppm, maximum water temperature in excess of 90°C/194°F. 
f) Problems associated with the chemistry of the water being heated (for example: rotten egg smell or inappropriate use of water softening equipment); 
g) Damages, malfunctions, or failures caused by using the indirect water heater to perform functions it was not designed to perform, abuse, accident, fire, flood, 
freeze, lightning, acts of God, and the like. 
h) Tank failures (leaks) caused by operating the indirect water heater in a corrosive or contaminated atmosphere. 
i) Damages, malfunctions, or failures caused by operating the indirect water heater with an empty, or partially empty, tank. 
j) Damages, malfunctions, or failures caused by operating the indirect water heater at water temperatures exceeding the maximum setting of the operating, or 
high limit, control. 
k) Tank failures caused by operating the indirect water heater when it is not supplied with potable water, free to circulate at all times. 
l) Damages, malfunctions, or failures caused by subjecting the tank to pressures greater than those shown on the rating label. 
m) Damages, malfunctions, or failures resulting from the use of any attachment, including any energy saving device, not authorized by Raypak. 
n) Indirect units installed outside the fifty states (and the District of Columbia) of the United States of America and its territories and the Dominion of Canada. 
o) Indirect units moved from the original installation location. 
p)  Indirect water heaters that have had their rating labels altered or removed. An indirect water heater should not be operated if the rating label is removed.

 

")DE*H!$)%&*#)"5H!5>#CC#+@H!)+'!C*EA&55#+@!AE5%5

!

This Limited Warranty does not cover any labor expenses for service, repairs, reinstallation, permits, or removal and disposal of a leaking indirect water heater or 
a defective component

 

part of an indirect water heater. All such expenses are the owner’s responsibility.

 

This Limited Warranty does not cover any reinstallation 

material costs for pipe, valves, fittings, or any other materials and/or services required to repair or replace a malfunctioning

 

indirect water heater or defective 

component part of an indirect water heater. All such expenses are the owner’s responsibility.

 

Raypak will pay the transportation costs for an “in-warranty” 

replacement indirect water heater, to a convenient

 

delivery point (selected by Raypak) near the place the original indirect water heater was purchased; such as a 

local Raypak water heater Distributor. The owner of the indirect water heater will be responsible for any local freight charges, including the cost of returning an 
indirect water heater, replaced “in-warranty” to a convenient location (selected by Raypak); such as a local Raypak water heater Distributor.

 

Raypak does not 

authorize, recommend, or receive any benefit from any warranty claims processing or similar fees charged by others to process warranty claims for any Raypak

 

indirect water heater. Raypak will not reimburse any party for these, or any other, fees not specifically covered in this Limited Warranty document.

 

Содержание RSIT115

Страница 1: ...not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas s...

Страница 2: ...2 Rev 1 Changes to New Additions New Deletions None...

Страница 3: ...cation 8 Boiler and Circulator Sizing 8 Temperature Pressure Relief Valve 8 Plumbing 8 Controls 11 START UP 13 Purging the System 13 Flushing the System 13 Checking Circulator 13 Set the Thermostat to...

Страница 4: ...es not answer please contact your local Raypak representative or visit our website at www raypak com Keep this manual with the water heater after installation Local plumbing and electrical codes must...

Страница 5: ...will be re placed in kind only per Raypak s standard warranties Scalding Water Temperature Setting DANGER Safety and energy conservation are factors to be considered when selecting the water temperatu...

Страница 6: ...cial Products 5th ed b The pressure of the heat transfer medium must be limited to a maximum of thirty 30 psig 207kPa by an approved safety or relief valve Freeze Protection The water heater and water...

Страница 7: ...al L First Hour Rating gal hr L hr Continuous Draw Rating gal hr L hr Standby Loss F hr C hr Minimum Boiler Ouptut BTUH kw Coil Length ft m Heating Surface Area Sq ft m2 Heating Coil Flow GPM L min Co...

Страница 8: ...ing should terminate in a safe location This discharge piping must comply with local and national plumbing codes The piping must be rated for 120 F and 150 PSI Plumbing A tempering valve may be requir...

Страница 9: ...BALL VALVE DRAIN TO BOILER COLD INLET HOT OUTLET FROM SYSTEM 12 MAX APART MIX OUTLET MAKE UP WATER TO SYSTEM COLD INLET S5 IND TANK SENSOR FROM BOILER INDIRECT FIRED STORAGE WATER HEATER DRAIN DRAIN F...

Страница 10: ...VALVE T P GAUGE UNION INLET OUTLET UNION UNION MIXING VALVE BALL VALVE PRV BALL VALVE S6 IND SUPPLY SENSOR BOILER PUMP EXPANSION TANK DHW PUMP DRAIN CHECK VALVE PRESSURE GAUGE BALL VALVE UNION BALL V...

Страница 11: ...SA control is pre configured to handle an indirect storage water heater The VERSA control can also be configured to give priority to the domestic hot water or to space heating To connect the unit to a...

Страница 12: ...r always remember that in principle an indirect water heater operates as another heating zone The difference is that when the indirect water heater calls for heat the indirect water heater cir culator...

Страница 13: ...ugh the tank to change the water vol ume at least two times Checking Circulator Check that the circulator or zone valve operates when there is a call for heat When a call for heat is initiated water s...

Страница 14: ...g Replace zone valve Circulator pump not working Check power supply Replace circulator Tank thermostat Thermostat set too low Check thermostat wiring Scale build up Check coil for scale build up Desca...

Страница 15: ...15 Below is a list of the replacement parts for the Stainless Steel Indirect Water Heater IPL diagram showing replacement parts 2 M 1 M 3 M PARTS...

Страница 16: ...lfunctions or failures resulting from failure to install the indirect water heater in accordance with applicable building codes ordinances or good plumbing and electrical trade practices c Damages mal...

Страница 17: ...tion for an in warranty indirect water heater replacement you must provide Raypak with at Raypak s option either the indirect water heater replaced in warranty with the original rating label and all t...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20 www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A...

Отзывы: