Note:
To exit the User Calibration pages at any
time, press and hold the
Depth
and
Speed
buttons
at the same time for approximately 2 seconds to
return to normal operation.
Depth Offset
Depths are measured from the transducer to the sea
bed, but you can apply an offset value to the depth
data, so that the displayed depth reading represents
the depth to the sea bed from either the keel or the
waterline.
Before attempting to set a waterline or keel
offset, find out the vertical separation between the
transducer and either the waterline or the bottom of
the keel on your vessel, as appropriate. Then set the
appropriate depth offset value.
D9343--2
1
2
3
1
Waterline offset
2
Transducer / Zero offset
3
Keel offset
If an offset is not applied, displayed depth readings
represent the distance from the transducer to the
sea bed.
Applying a Depth Offset
From the
User Calibration Menu
:
1. Press the
Depth
button until the
Depth Offset
page is displayed (2 presses from the
User
Calibration
page).
D12440-2
D
e pth
2. Use the
Trip
and
Reset
buttons to select the
required depth offset value.
The depth offset can be set to the following
values:
•
Keel
— values between –9.9 to –0.1
•
OFFSET
(default)
(Zero Offset) — 0.0
•
W/L
(Waterline) — values between 0.1 to 9.9
Note:
To exit the User Calibration pages at any
time, press and hold the
Depth
and
Speed
buttons
at the same time for approximately 2 seconds to
return to normal operation.
Selecting the unit of measure for speed
readings - i50 Tridata
From the
User Calibration Menu
.
1. Press the
Speed
button until the
Speed Units
page is displayed (1 press from the
User
Calibration
page)
D12442-2
S
pe e d
2. Use the
Trip
and
Reset
buttons to select the
required unit of measurement for speed readings.
The units of measure available for speed
readings are:
• KTS — Knots (default)
• MPH — Miles Per Hour
• KMH — Kilometers Per Hour
Note:
To exit the User Calibration pages at any
time, press and hold the
Depth
and
Speed
buttons
at the same time for approximately 2 seconds to
return to normal operation.
Selecting a speed resolution
From the
User Calibration Menu
.
1. Press the
Speed
button until the
Speed
Resolution
page is displayed (2 presses from
the
User Calibration
page).
D12443-2
S
pe e d
2. Use the
Trip
and
Reset
buttons to select the
required resolution for speed readings.
The resolutions available are 0.01 (default) and
0.1.
Note:
To exit the User Calibration pages at any
time, press and hold the
Depth
and
Speed
buttons
at the same time for approximately 2 seconds to
return to normal operation.
Selecting the unit of measure for log readings
From the
User Calibration Menu
.
1. Press the
Speed
button until the
Log Units
page is displayed (3 presses from the
User
Calibration
page).
D12444-2
S
pe e d
2. Use the
Trip
and
Reset
buttons to select the
required unit of measurement for log readings.
•
KM (default)
— Kilometers
•
SM
— Statute Miles
•
NM
— Nautical Miles
Note:
To exit the User Calibration pages at any
time, press and hold the
Depth
and
Speed
buttons
at the same time for approximately 2 seconds to
return to normal operation.
i50 Tridata
59
Содержание i50 Depth
Страница 2: ......
Страница 4: ......
Страница 10: ...10 i50...
Страница 29: ...Chapter 5 Mounting Chapter contents 5 1 Mounting on page 30 5 2 Front bezel on page 31 Mounting 29...
Страница 32: ...32 i50...
Страница 42: ...42 i50...
Страница 78: ...78 i50...
Страница 86: ...86 i50...
Страница 88: ...88 i50...
Страница 89: ......
Страница 90: ...www raymarine com...