7.8 Dealer calibration — i50 Speed
The dealer calibration procedures include:
• User calibration menu access On (default) and Off.
• Display Response for speed readings — Dictates
the rate at which the instrument display responds
to changes in speed data.
• Display Response for Velocity Made Good
(VMG) readings — Dictates the rate at which the
instrument display responds to changes in VMG
data.
• Boat show mode On and Off (default) (Boat
show mode is only available on displays set as
repeaters).
• Reset to factory defaults.
Accessing the Dealer Calibration Menu
During normal operation:
1. Press and hold the
Speed
and
Trip
buttons at the
same time for approximately 14 seconds, until
the
Dealer Calibration
page is displayed.
+
D12475-2
1
0
15
20
25
30
35
40
45
50
55
60 5
14
S
pe e d
T
rip
Note:
To exit the Dealer Calibration pages at any
time, press and hold the
Speed
and
Trip
buttons
at the same time for approximately 2 seconds.
Setting access to the User Calibration Menu
From the Dealer Calibration page:
1. Press the
Timer
and
Reset
buttons at the same
time to display the
User Calibration Access
page.
D12476-2
+
T
ime r
R
e s e t
2. Use the
Timer
and
Reset
buttons to switch
access to the
User Calibration Menu
On (default) and Off.
Selecting Off disables access to the
User
Calibration Menu
.
Note:
To exit the Dealer Calibration pages at any
time, press and hold the
Speed
and
Trip
buttons
at the same time for approximately 2 seconds.
Setting the response delay for speed
readings
From the
User Calibration Menu Access
page:
1. Press the
Speed
button until the
Speed
Response
page is displayed (1 press from User
Calibration Menu Access
page).
D12477-2
S
pe e d
2. Use the
Timer
and
Reset
buttons to adjust the
speed response to the required level.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note:
To exit the Dealer Calibration pages at any
time, press and hold the
Speed
and
Trip
buttons
at the same time for approximately 2 seconds.
Setting the response delay for VMG (wind)
readings
From the
User Calibration Menu Access
page:
1. Press the
Speed
button until the
VMG Response
page is displayed (2 presses from User
Calibration Menu Access
page).
D12478-2
S
pe e d
2. Use the
Timer
or
Reset
buttons to adjust the
VMG response to the required level.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note:
To exit the Dealer Calibration pages at any
time, press and hold the
Speed
and
Trip
buttons
at the same time for approximately 2 seconds.
Enabling and disabling Boat Show Mode
From the User
Calibration Menu Access
page:
1. Press the
Speed
button until the
Boat Show
Mode
page is displayed (3 presses from
User
Calibration Menu Access
page).
D12479-2
S
pe e d
2. Use the
Timer
and
Reset
buttons to switch boat
show mode On and Off (default).
Selecting On will put the display into boat show
mode.
Note:
Boat show mode is only suitable for
demonstration purposes and should NOT be used
whilst your vessel is in use.
Note:
To exit the Dealer Calibration pages at any
time, press and hold the
Speed
and
Trip
buttons
at the same time for approximately 2 seconds.
Resetting the display to factory defaults
From the User
Calibration Menu Access
page:
1. Press the
Speed
button until the
Factory
Defaults
page is displayed (4 presses from
User
Calibration Menu Access
page).
D12480-2
S
pe e d
2. To reset the display to factory default settings:
i50 Speed
51
Содержание i50 Depth
Страница 2: ......
Страница 4: ......
Страница 10: ...10 i50...
Страница 29: ...Chapter 5 Mounting Chapter contents 5 1 Mounting on page 30 5 2 Front bezel on page 31 Mounting 29...
Страница 32: ...32 i50...
Страница 42: ...42 i50...
Страница 78: ...78 i50...
Страница 86: ...86 i50...
Страница 88: ...88 i50...
Страница 89: ......
Страница 90: ...www raymarine com...