Markers — side view
D13147-1
1
2
1.
Front marker
2.
Rear marker
When the 2 markers appear vertically aligned
the vessel is on the correct range line to begin a
measured mile run.
Marker alignment
D13148-1
1
2
3
1.
Left of range line
2.
On range line
3.
Right of range line
The vessel should already be at top speed and as
the first pair of markers appear aligned a stopwatch
should be started, when the vessel passes the
second pair of aligned markers the stopwatch is
stopped.
Measuring a nautical mile
5
4
D13149-1
3
1
2
1.
Starting point (start stopwatch)
2.
Measured mile
3.
End point (stop stopwatch)
4.
First pair of markers
5.
Second pair of markers
To provide a more accurate reading the vessel
should make between 4 to 6 runs in both directions
to allow for tide and wind conditions. The average
of the time taken over all runs should be used to
calculate Log Speed.
The vessel speed can then be worked out by taking
the distance travelled (1 nautical mile) and dividing it
by the average time taken to perform the run . The
resulting calculation is your average speed in knots.
Selecting unit of measure for water
temperature readings
From the
User Calibration Menu
:
1. Press the
Speed
button until the
Water
Temperature Units
page is displayed (5 presses
from the
User Calibration
entry page).
D12434-2
S
pe e d
2. Use the
Timer
or
Reset
buttons to select
the required unit of measurement for water
temperature readings.
The units of measure available for temperature
are:
•
°C
(default)
— degrees Celsius
•
°F
— degrees Fahrenheit
Note:
To exit the User Calibration pages at any
time, press and hold the
Speed
and
Trip
buttons
at the same time for approximately 2 seconds.
Calibrating water temperature
You will need an suitable thermometer to measure
the water temperature.
From the
User Calibration Menu
:
1. Press the
Speed
button until the
Water
Temperature Calibration
page is displayed (6
presses form the
User Calibration
entry page).
D12435-2
S
pe e d
2. Use a suitable thermometer to measure the water
temperature.
3. Use the
Timer
and
Reset
buttons to match
the displayed water temperature to the water
temperature measured by the thermometer.
Note:
To exit the User Calibration pages at any
time, press and hold the
Speed
and
Trip
buttons
at the same time for approximately 2 seconds.
Enabling and disabling timer buzzers
From the
User Calibration Menu
:
1. Press the
Speed
button until the
Timer Buzzer
page is displayed (76 presses form the
User
Calibration
entry page).
D12436-2
S
pe e d
2. Use the
Timer
or
Reset
buttons to switch the
timer buzzers On and Off (default).
48
i50
Содержание i50 Depth
Страница 2: ......
Страница 4: ......
Страница 10: ...10 i50...
Страница 29: ...Chapter 5 Mounting Chapter contents 5 1 Mounting on page 30 5 2 Front bezel on page 31 Mounting 29...
Страница 32: ...32 i50...
Страница 42: ...42 i50...
Страница 78: ...78 i50...
Страница 86: ...86 i50...
Страница 88: ...88 i50...
Страница 89: ......
Страница 90: ...www raymarine com...