Setting dealer calibration options - i50 Tridata
During normal operation:
1. Press and hold the
Depth
and
Speed
buttons simultaneously
for approximately 14 seconds to display the dealer calibration
entry page.
De pth
+
S pe e d
D12481-1
1
0
15
20
25
30
35
40
45
50
55
60 5
14
2. Press the
Trip
and
Reset
buttons simultaneously to display the
user calibration access page.
+
D12482-1
Re s e t
Trip
3. Press the
Depth
button to display the speed select page.
D12483-1
De pth
4. Use the
Trip
or
Reset
buttons to switch the speed data source
on and off.
5. Press the
depth
button to display the speed response page.
D12484-1
De pth
6. Use the
Trip
or
Reset
buttons to set the required speed
response value.
7. Press the
Depth
button to display the depth response page.
D12485-1
De pth
8. Use the
Trip
or
Reset
buttons to set the required depth response
value.
9. Press the
Depth
button to display the boat show mode page.
D12486-1
De pth
10. Use the
Trip
or
Reset
buttons to switch boat show mode on
and off.
11. Press the
Depth
button to display the factory reset page.
D12487-1
De pth
12. Use the
Trip
or
Reset
buttons to reset the units settings to
factory default values
13. To exit the Dealer calibration pages at any time, press and hold
the
Depth
and
Speed
buttons simultaneously for approximately
2 seconds.
Getting started
37
Содержание E70058
Страница 2: ......
Страница 4: ......
Страница 6: ...6 i50 ...
Страница 18: ...18 i50 ...
Страница 24: ...24 i50 ...
Страница 38: ...38 i50 ...
Страница 45: ...Chapter 8 Using alarms Chapter contents 8 1 Alarms on page 46 Using alarms 45 ...
Страница 64: ...13 4 Converters Part number Description E22158 SeaTalk to SeaTalkng Converter 64 i50 ...
Страница 66: ...66 i50 ...
Страница 67: ......
Страница 68: ...www raymarine com ...