9. If the SOG page is displayed and the tide conditions are slack,
press and hold the
Reset
button for 3 seconds to accept SOG
as the current speed.
D12447-1
Re s e t
1
0
15
20
25
30
35
40
45
50
55
60 5
3
10. Alternatively, with the cal factor page displayed use the
Trip
or
Reset
buttons to set the cal factor to your vessel's estimated
current speed.
11. Press the
Speed
button to display the temperature units page.
D12448-1
S pe e d
12. Press the
Speed
button to display the temperature calibration
page.
D12449-1
S pe e d
13. Use the
Trip
or
Reset
buttons to set the unit to show the current
water temperature.
14. Press the
Speed
button to display the Timer buzzer page.
D12450-1
S pe e d
15. Use the
Trip
or
Reset
buttons to switch the count-up and race
start timer buzzers on and off.
16. To exit the user calibration pages at any time, press and hold the
Depth
and
Speed
buttons simultaneously for 2 seconds.
Intermediate calibration
Intermediate calibration allows you to:
i50 Depth
i50 Speed
i50 Tridata
Check instrument
software version.
Check instrument
software version.
Check instrument
software version.
Check and if necessary
change the instrument
status (either master or
repeater).
Check the instrument
status (either master or
repeater).
Check and if necessary
change the instrument
status (either master or
repeater).
Carry out a calibration
run over a measured
distance to ensure
accurate speed
readings.
Carry out a calibration
run over a measured
distance to ensure
accurate speed
readings.
Checking i50 Depth software version and status
Depth
Alarm
1
0
15
20
25
30
35
40
45
50
55
60 5
4
+
Depth
D12451-1
During normal operation:
1. Press and hold the
Depth
and
Alarm
buttons simultaneously
for 4 seconds:
The software version is displayed.
2. Press the
Depth
button to display the instrument status.
Master (transducer connected) or Repeater (No transducer
connected).
3. To change the status:
i.
Press the
Offset
and
Reset
buttons simultaneously to enter
adjust mode.
The status flashes when in adjust mode.
ii. Press either
Offset
or
Reset
to switch the status between
Master or Repeater.
4. To exit the Intermediate calibration settings at any time, press
and hold the
Depth
and
Alarm
buttons simultaneously for 4
seconds.
Checking i50 Speed software version and status
Speed
Trip
1
0
15
20
25
30
35
40
45
50
55
60 5
4
+
Speed
D12452-1
During normal operation:
1. Press and hold the
Speed
and
Trip
buttons simultaneously for
4 seconds:
The software version is displayed.
2. Press the
Speed
button to display the instrument status.
Master (transducer connected) or Repeater (No transducer
connected).
3. Press the
Speed
button again to begin speed run calibration.
4. To exit the Intermediate calibration settings at any time, press
and hold the
Speed
and
Trip
buttons simultaneously for 4
seconds.
Performing speed run calibration – i50 Speed
This speed calibration involves carrying out up to 2 runs over a
measured distance, to enable a calibration factor to be determined
and applied to your unit. Each run consists of an outward and a
return leg, to minimize the effect of tidal drift when the calibration
factor is determined.
From the Intermediate calibration page:
Note:
This procedure is not required if current speed is set to
SOG.
1. Press the
Speed
button until you reach the Calibration run
length page.
D12453-1
S pe e d
2. Press the
Timer
and
Reset
buttons simultaneously to enter
adjust mode.
D12454-1
R
e s e t
Time r
+
In adjust mode the run length flashes.
3. Use the
Timer
or
Reset
button to set the run length to the
required value (between 0.25 and 2.50).
4. Press the
Timer
and
Reset
buttons simultaneously to commence
the speed run calibration
The calibration status page is displayed. The text at the top of
the page alternates between START 1 and the calibration factor
currently applied.
D12455-1
Re s e t
Time r
+
5. Start the outward leg of the calibration run and as you pass the
start point, press the
Trip
button, so the page shows OUTWARD
at the top. As the calibration run proceeds, the displayed value
will change.
D12456-1
Trip
34
i50
Содержание E70058
Страница 2: ......
Страница 4: ......
Страница 6: ...6 i50 ...
Страница 18: ...18 i50 ...
Страница 24: ...24 i50 ...
Страница 38: ...38 i50 ...
Страница 45: ...Chapter 8 Using alarms Chapter contents 8 1 Alarms on page 46 Using alarms 45 ...
Страница 64: ...13 4 Converters Part number Description E22158 SeaTalk to SeaTalkng Converter 64 i50 ...
Страница 66: ...66 i50 ...
Страница 67: ......