Alarms menu
The Alarms available are dependent on the display variant.
Alarm
Description
Options
Deep Water Arrival
When set to On, an alarm is triggered when the
depth reaches the value specified in the
Deep
Limit
setting. This option is only available when
current depth data is available.
Note:
The
Deep limit
cannot be set to a value
less than the
Shallow Limit
.
Deep:
• Off (default)
• On
Deep Limit:
• 2 ft (or equivalent units) to the maximum of the
transducer range
Shallow Water
Arrival
When set to On, an alarm is triggered when the
depth reaches the value specified in the
Shallow
Limit
setting. This option is only available when
current depth data is available.
Note:
The
Shallow Limit
cannot be set to a depth
greater than the
Deep Limit
.
Shallow:
• Off (default)
• On
Shallow Limit:
• 2 ft (or equivalent units) to the maximum of the
transducer range
Fish
If the Fish alarm and fish depth limits alarm are set
to On, a warning sound is triggered if any target
meets the sensitivity level and is within the Shallow
Fish Limit and Deep Fish Limit that you specify.
The following items are available in the sub-menu:
•
Fish
— Switches fish alarm On and Off.
•
Fish Sensitivity
— If the Fish alarm is set to
On, an alarm is triggered when the fish return
strength reaches the sensitivity that you specify.
•
Fish Depth Limits
— Switches depth limits On
and Off.
•
Shallow Fish Limit
— Specifies the lower value
for the Fish Alarm Depth Limit.
•
Deep Fish Limit
— Specifies the upper value
for the Fish Alarm Depth Limit.
Fish
• Off (default)
• On
Fish Sensitivity
• 1 to 10
Fish Depth Limits
• On
• Off (default)
Shallow Fish Limit
• 2 ft (or equivalent units) to the maximum of the
transducer range
Deep Fish Limit
• 2 ft (or equivalent units) to the maximum of the
transducer range
Water Temperature
When set to On, an alarm and pop-up message is
triggered when the water temperature is equal to
or lower than the Lower Temp Limit, or equal to or
greater than the Upper Temp Limit.
Water Temperature
• Off (default)
• On
Lower Temp Limit
• 60 degrees fahrenheit (or equivalent units)
• –09.9 to +99.7 degrees fahrenheit (or equivalent
units)
Upper Temp Limit
• 75 degrees fahrenheit (or equivalent units)
• –09.7 to 99.9 degrees fahrenheit (or equivalent
units)
Waypoint Arrival
Alarm
When you arrive at a waypoint, an alarm is
triggered. This setting allows you to specify the
distance from the target waypoint at which the
alarm is triggered.
0.01 to 9.99 nm (or equivalent units)
90
Dragonfly 6 / Dragonfly 7
Содержание Dragonfly 6
Страница 2: ......
Страница 4: ......
Страница 24: ...24 Dragonfly 6 Dragonfly 7...
Страница 82: ...82 Dragonfly 6 Dragonfly 7...
Страница 96: ...96 Dragonfly 6 Dragonfly 7...
Страница 104: ...104 Dragonfly 6 Dragonfly 7...
Страница 108: ...108 Dragonfly 6 Dragonfly 7...
Страница 109: ...Chapter 13 Technical specification Chapter contents 13 1 Technical specification on page 110 Technical specification 109...
Страница 112: ...112 Dragonfly 6 Dragonfly 7...
Страница 113: ...Chapter 14 Spares and accessories Chapter contents 14 1 Accessories on page 114 Spares and accessories 113...
Страница 115: ......
Страница 116: ......