Chapter 1 

Basic Information 

RAYLASE IPG Interface Board 

MN027 / v1.1.0 

BASIC INFORMATION 

The RAYLASE IPG interface board is used to control a pulsed IPG laser in combination with 
RAYLASE control cards SP-ICE, RLC-PCI or RLC-USB. 

Features 

  Interface to Ytterbium pulsed IPG Fiber Lasers according to interface types B, B1, B2, D 

  D-SUB 25 connector for 1:1 connection to pulsed IPG laser 

  Detection, if 24V power is attached. Soft start to switch on the laser. 

  Optically isolated control signals 

  Detection of laser error conditions 

  Reset of laser after detection of laser error either by push-button or software 

  Support of integrated visible pointer 

  Emergency Stop input for immediate shut off of laser output 

1.1 

Delivery Scope  

  IPG interface board 

  Connecting cable between IPG interface board and control card 

  Laser adaptor 

  Hardware manual 

1.2 

Warranty 

The rights of the customer in respect of any defects in quality or deficiencies in title are gov-
erned by the general conditions of business of RAYLASE AG. These conditions are available 
for review on our website.  

Before returning the product, please request an authorization number from RAYLASE. Pack 
the product in the original packaging or in packaging that provides equivalent protection for 
shipping. 

RAYLASE shall not be obliged to repair defects under the following circumstances: 

  If persons not authorized by RAYLASE have attempted to repair the product. 

  If persons not authorized by RAYLASE have modified the product. 

  If the product has been used improperly. 

  If the product has been connected to incompatible devices. 

  If the product has been damaged because of inadmissible high laser power or focusing the 

laser on optical areas. 

  If the product has been damaged because of unqualified cleaning of the optical areas. 

Note:

 No implicit guarantee or warranty of suitability for specific purposes has been made. 

RAYLASE is not responsible for damages arising from use of the product. Individual assem-
blies or other assemblies manufactured by RAYLASE may be subject to separate warranty 
conditions. Refer to the corresponding manuals for further information. 

 

Содержание IPG

Страница 1: ...Hardware Manual IPG Interface Board ...

Страница 2: ...the infor mation contained therein without prior notice The software included in the product and this manual itself are protected by copyright All rights are reserved Duplication of this manual in whole or in part particularly by photocopy ing scanning or imaging and reproduction by any means are forbidden without the prior writ ten consent of RAYLASE ...

Страница 3: ...fety 6 1 6 Manufacturer 6 1 7 Customer Support 6 1 8 Disposal 6 2 TECHNICAL DATA 7 2 1 Dimension and Weight 7 2 2 Environmental Conditions 7 2 3 SET UP Procedure 7 2 4 Connections 8 2 4 1 IPG Laser Interface 9 2 4 2 Laser Power Input and Laser Power Output 10 2 4 3 Cable Specifications 10 2 4 4 Status LEDs 10 3 PROGRAMMING 11 3 1 Signals 11 3 2 Commands 11 3 3 Programming sequence 12 ...

Страница 4: ...d by the general conditions of business of RAYLASE AG These conditions are available for review on our website Before returning the product please request an authorization number from RAYLASE Pack the product in the original packaging or in packaging that provides equivalent protection for shipping RAYLASE shall not be obliged to repair defects under the following circumstances If persons not auth...

Страница 5: ...he CE symbol confirms the compliance of the Interface Board with European directives It indicates that the Interface Board is approved for free trade within the EU The seal label warns against unauthorized opening of the In terface Board If the seal is broken all warranty claims against RAYLASE are void 1 4 Conformity with directives The Interface Board conforms to the requirements of the followin...

Страница 6: ...49 0 81 53 88 98 10 http www raylase de E mail info raylase de 1 7 Customer Support The RAYLASE support services are available for your problems either in respect to the prod uct or the accompanying manual Before calling for support please make sure you refer to any appropriate sections in this manual that may answer your questions If you need further assistance call RAYLASE customer service depar...

Страница 7: ...n head manuals are fulfilled It is the user s responsibility to follow the regulations on laser safety Control card IPG laser IPG interface board Adap ter J3 J2 J4 Power supply J1 J5 Shutter Installation Connect power supply for laser to J1 Connect laser power supply output J2 to IPG laser Connect IPG interface board output J4 to laser interface Connect RAYLASE control card via adapter to IPG inte...

Страница 8: ...signment Details J1 Laser Power Input 24V J2 Laser Power Output J3 IPG Interface Input J4 IPG Interface Output page 9 J5 Shutter Emergency Stop must be connected to switch on the laser T1 Laser Reset resets the laser or the IPG interface in case of a fault Fig 2 IPG interface board overview ...

Страница 9: ...3 17 nc 5 D4 18 MO EE 6 D5 19 Laser Modulation 7 D6 20 PRR Sync interface type D 8 D7 21 Alarm2 9 Latch 22 Pointer 10 GND 23 Emergency stop 11 Alarm3 24 nc 12 Alarm4 25 nc 13 nc EE Emission Enable LM Laser modulation MO Master oscillator interface type B nc Not connected PRR Pulse Repetion Rate interface type B Specifications Output Output low max 0 55V 64mA Output high 2 0 5 0V 32mA ...

Страница 10: ...us LEDs LED Meaning 1 2 3 4 green 5V Input Voltage from control card is ready green 24V Input Voltage for laser is ready red 24V Output Soft start process of IPG laser is active green IPG laser is powered up red Laser emission ON Laser is active LED Meaning 5 6 7 green green green Normal state yellow green green Laser not ready only interface type D yellow Shutter open combinations with other faul...

Страница 11: ...Off the Master Oscillator Input of IPG Laser FPS Setting Power Setting Latch Input of IPG Laser PB 0 7 Setting 8 Bit Power Inputs of IPG Laser LM_Gate Switching On Off the Laser Modulation Input of IPG Laser Remote_Execute 1 Reset IPG Laser after Detection of Alarm Condition PA 6 Reading of combined Alarm1 to Alarm3 outputs of IPG Laser 3 2 Commands To program the IPG interface board use the follo...

Страница 12: ...ute Job Write_Port 0x0C 0x0000 Switch Off Master Oscillator of IPG Laser Setting Master Oscillator input of IPG Laser with List Commands Set_Start_List_1 Filling Job Data into List 1 Write_Port_List 0x0C 0x0010 Switch On Master Oscillator of IPG Laser Long_Delay 1000 Wait 10msec Set_Delays_7_8 t1 t2 Set Laser Modulation Signal Set_Delays_9_10 t3 t4 t4 0 Write_Port_List 0x0A value Set Laser Power L...

Страница 13: ...th directives 5 Connections 8 Customer Support 6 D Delivery Scope 4 Dimension 7 Disposal 6 E Environmental Conditions 7 F Features 4 I Installation 7 L Laser Safety 6 7 M Manufacturer 6 R Rating plate 5 S Seal label 5 SET UP Procedure 7 Signs 5 T Technical Data 7 W Warranty 4 Weight 7 ...