Chapter 2
Technical Data
10
RAYLASE IPG Interface Board
MN027 / v1.1.0
2.4.2
Laser Power Input and Laser Power Output
J1, J2
PIN
Signal
1
2 3
Laser power
interconnection
1
24V
2
Return
3
Safety Ground
2.4.3
Cable Specifications
Connection
Cross-section
Length
Signals
24V power supply
− J1
min. 3x2,5mm²
---
---
J2
− IPG laser
min. 3x2,5mm²
max. 2m
---
J4
− IPG laser
---
max. 2m
1:1
2.4.4
Status LEDs
LED
Meaning
1
2
3
4
green
-
-
-
5V Input
Voltage from control card is ready
-
green
-
-
24V Input
Voltage for laser is ready
-
-
red
-
24V Output
Soft start process of IPG laser is active.
-
-
green
-
IPG laser is powered up
-
-
-
red
Laser emission ON
Laser is active
LED
Meaning
5
6
7
green
green
green
Normal state
yellow
green
green
Laser not ready (only interface type D)
yellow *
-
-
Shutter open (combinations with other fault possible)
-
-
red
Laser temperature out of range
-
red
-
Powersupply out of range (only interface type D)
red
-
-
Back Reflection error
red*
red*
red*
Internal system error
* flashing
Содержание IPG
Страница 1: ...Hardware Manual IPG Interface Board ...