Item
Level
Action
Suggested
Description
Low
High
FCC (mAh/Wh)
√
√
√
√
Learning
FCC represents the last measured capacity during a
full discharge of the battery. Initially Full Charge
Capacity should equal to the Design Capacity and it
is modified over the course of pack usage to reflect
cell aging under the particular use conditions. The
FCC value has dropped to under 30% of the Design
Capacity. User can try to re-learn the battery to gain
more performance but it is recommended to
replace the pack in order to maintain the
performance of the Laptop.
RSOC (%)
√
√
√
√
Charge
The battery remaining capacity has exceeded the
usage high/low limit. It is recommended to
Discharge/Charge the battery back to normal
operational capacity.
When the battery is too low and the Battery LED
light OFF, it is suggested to use waken charge to
recover the battery before any test.
RSOC (%)
√
√
√
√
Discharge
Voltage
Vs
RSOC (%)
Not at the same
Level
Learning
Voltage and RSOC both represent the level of
capacity in the battery pack. Voltage is the physical
measurement while the RSOC is a calculated by the
SMBus Gas Gauge IC. Over a long period of usage or
when the battery is not properly learned, these two
values might not be synchronized. The result of this
might cause the reduction of working hours of the
battery. Learning is suggested to re-synchronize
these
two
parameters
and
improve
the
performance of the battery.
N/A appears in all read
values field
√
√
√
√
Wakening
If N/A appears in all read values field, it is suggested
that the user to check if the connection is correct.
Otherwise user should use the wakening to recover
the faulty battery.
Notices: Out of Range, all SMBus Register values will have their own physical range, if the read values are out of the defined