Wuhan Raycus Fiber Laser Technologies CO., Ltd.
Pulsed Fiber Laser User’s Guide V2.1
2
e)
Do not install the collimating device into the output head when the laser device is in
working.
f)
The device has three cooling fans at the rear panel to dissipate heat. In order to
guarantee enough airflow to help giving heat off, there must be a space of at least
10cm’s width for airflow in front and rear side of the device. As the cooling fans are
working at blow condition, if laser is mounted in a cabinet with fans, the direction
should be same as laser’s fans.
g)
Do not look into the output head of the device directly. Please do wear appropriate
laser safety eyewear during the time when operating the device.
h)
Make sure the pulse repetition rate higher than 20kHz.
i)
For the longest time without pulse is only 50 x 10
-6
s. If there is no pulse output, please
stopmarking at once, to avoid further damage of the device.
j)
Power source sudden interruption will do great harm to the laser device. Please make
sure the power supply works continuously.
1.4.
Specifications
Table 2.pulsed fiber laser specifications
Pulsed fiber laser
20
Wavelength
(
nm
)
1064
±
5
Polarization
Random
Optical isolator
Yes
Nominal average output power (W)
≥
20
Single pulse energy (mJ)
1@20kHz
Beam quality
(
M
2
)
<1.5
Beam Diameter
(
mm
)
6
~
8
Pulse duration
(
ns
)
90-110@20kHz
Pulse repetition rate
(
kHz
)
20-60
Output Power Tunability
(
%
)
10-100
Output Fiber Cable length
(
m
)
3
Working voltage
(
VDC
)
24±1
Power consumption
(
20
℃)(
W
)
170
Cooling
Forced Air Cooled
Dimension W×D×H
(
mm
)
260×391×120
Operating temperature
(℃)
0
℃~
40
℃
Store temperature
(℃)
-20
℃~
60
℃
humidity
(
%
)
≤80