background image

Wuhan  Raycus  Fiber  Laser  Technologies  CO.,  Ltd.

 

  Pulsed Fiber Laser User’s Guide V2.1

 

 

 

19 at least 5 ms, and otherwise the laser machine may be damaged. 

Table 4 Definition of power control PIN value 

 

Setting 1  Setting 2  Setting 3  Setting 4 

Setting 5 

PIN 1 

PIN 2 

PIN 3 

PIN 4 

PIN 5 

PIN 6 

PIN 7 

PIN 8 

Current 

~50 % 

~75 % 

~87.5 %  ~93.75 % 

100% 

e)

 

PIN  20  provides  control  of  the  frequency.  The  frequency  range  should  be  20kHz~60 

kHz, depends on the varying power levels of different laser machines. 

ATTENTION: The frequency signal must be ahead of the EM signal at least 5 ms, 

otherwise the laser machine may be damaged.

 

f)

 

Definition of alarm signal 

Table 5 Definition of warning signal

 

 

PIN 12 

PIN 11 

PIN 16 

PIN 21 

Alarm item 

×

 

Low 

Low 

Low 

Temperature alarm 

×

 

Low 

Low 

High 

Normal 

×

 

Low 

High 

High 

System alarm 

×

 

High 

Low 

Low 

Supply voltage 

 

g)

 

Internal circuit of input/output signal 

Internal circuit of input signal

(current of input signal must be greater than 7mA) 

 

Figure 6. Internal circuit of input signal 

Содержание RFL-P20Q

Страница 1: ...A0 C RFL P20Q 20Q RFL P20Q JS02 20210303 20210305 20210305 20210305 20210308...

Страница 2: ...User Instruction RFL P20Q Wuhan Raycus Fiber Laser Technologies CO Ltd 2021...

Страница 3: ...vice Before supplying the power to the device please make sure that the correct voltage of 24V DC power source is connected and the anode and cathode are right Failure to connect power source correctl...

Страница 4: ...ironmental requirements and cautions 1 1 4 Specifications 2 2 Mounting 3 2 1 Mounting dimensions 3 2 2 Method of installation 3 3 Control Interface 4 4 Operation Regulations 7 4 1 Pre inspection 7 4 2...

Страница 5: ...ion list Table 1 Configuration list Items Quantity Remark Fiber Laser module 1 User Guide 2 1 3 Environmental requirements and cautions Pulsed laser should be driven by 24V DC 1V power source a Cautio...

Страница 6: ...device h Make sure the pulse repetition rate higher than 20kHz i For the longest time without pulse is only 50 x 10 6 s If there is no pulse output please stopmarking at once to avoid further damage...

Страница 7: ...laser module Unit mm b Isolated output head dimensions As shown in Fig 2 Figure 2 Dimension drawing of output isolator Unit mm 2 2 Method of installation a Fix the module stable to the bracket and kee...

Страница 8: ...B25 Controller interface Power supply wire Laser Module 24V Brown L N GND External GND 24V power supply 24V Blue Figure 4 Schematic of recommended electrical connection d The bending radius of the del...

Страница 9: ...1V Emission OFF 20 Sync Pulse Repetition Rate Synchronization input square wave 22 Guide Laser signal Guide Laser red diode ON OFF input 9 23 Obligate PIN Reserved for Raycus only a The pump current o...

Страница 10: ...rol of the frequency The frequency range should be 20kHz 60 kHz depends on the varying power levels of different laser machines ATTENTION The frequency signal must be ahead of the EM signal at least 5...

Страница 11: ...east 1 minute since the power turned on the subsequent operations can be preceded b Frequency set introductions For modelP20Q the frequency setting range is from 20kHz to 60kHz c Laser marking checkin...

Страница 12: ...or reimbursement of our product of which the problem results from tampering disassembling misuse accident modification unsuitable physical or operating environment improper maintenance damages due to...

Страница 13: ...r Laser User s Guide V2 1 9 All the items about warranty and service above provided by Raycus are only for reference formal contents about warranty and service are subject to the contract 2021Wuhan Ra...

Отзывы: