Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL- RFL-C8000S
21
report for details
)
14
Isolated Analog
Com
GND1
Return
---
---
---
Return for signals on pins
12, 13,19,22,23,24
15
Mod
MOD+
Digital Input 5-24VDC
6 mA
20µs
5 -24 VDC Input
16
Modulation-
MOD—
Return
Return for signal on pin 15
17
Guided Laser
Control
RED-LAS
ER
Digital Input
5-24Vdc
6 mA
120ms
Positive edge activates
emission in REM mo
de
18
Emission
Enable
LAS—C
Digital Input 5-24VDC
6 mA
1ms
Positive edge activates
emission in REM mode
19
System error
(
ERROR
)
S-ERR
Digital
output
24VDC
100mA
120ms
High=System error
20
System Common
GND2
Return
Return for pin 17
、
18
、
21
21
Error RESET
RESET
Digital Input 5-24VDC
6 mA
120ms
Rising edge reset (the
resettable alarm)
22
READY
READY
Digital
output
24VDC
100mA
120ms
High=Laser is ready
23
Power started
POWER
Digital
output
24VDC
100mA
120ms
High=The main power
supply is started
24
Laser emission
LASER
Digital
output
24VDC
100mA
100ms
High=Laser is emission
Caution: Please check the control voltage level and ensure that the level is in
accordance with the requirements. Over voltage and voltage ripple may damage
the product.
The Service Security Interface is pin 2-3 and pin 1-4 of CTRL-INTERFACE. If the pin 2-3
and pin 1-4 are disconnected, the laser will immediately stop emitting light, and the laser Ready
signal output will change to low level. Be sure to short-circuit pin 2-3 and pin 1-4 before using
the laser. If it is not short-circuited, the laser will display Interlock alarm after power-on.
Interlock interface must not be connected to active signal, otherwise it
will cause interface damage and laser alarm.