26
changes of the guide laser external control state in the software. If the current red external
control state, then disable the red control button.
Read and set the parameters of rise time and fall time: The rise time and fall time can be set
separately and must be an integer ranging from 0 to 61000.
Read and Set Program Number: The program number is displayed in the drop-down list box.
When you click the drop-down list box, the program number saved on the main control board is
loaded. Only the valid program number is displayed. The default value is "Not set",
corresponding to the program number "0". When you click Read, the current program number is
read from the main control board. If the read program number is “0” and “unset” is displayed,
otherwise, the read program number is displayed. When you click "Set", if "Not set" is selected,
the program number is set to "0", indicating that the program mode is not currently used;
otherwise, the program number is set to the currently selected program number. When the
software is started, the program number set on the current main control board is automatically
read and displayed.
Control laser parameters: Optical output parameters include power, frequency, pulse width,
and duty cycle. The communication between the software and the main control board requires
only power, frequency, and pulsewidth. The duty cycle can be calculated from the pulse width
and frequency, and the pulse width can also be calculated from the duty cycle and frequency.
During the software operation, the frequency and duty cycle will be changed synchronously with
the pulse width, and the duty cycle will also be changed synchronously with the frequency and
duty cycle. The output power can be an integer in the range of (0,100). The frequency can be set
to a decimal in the range of (0,5000). The duty cycle can be set to a decimal in the range of
(0,100).
Control light emission mode: light emission related modes include AD mode, external
enable, external modulation mode, and internal modulation mode. You can individually control
the opening and closing of each mode, and display the current status of each mode. After the AD