Monitor mode:
The monitor mode is selected by default when the software is opened.
The most commonly used and concerned information is displayed on the software interface to
avoid the interference of too much information to the user. The monitor mode can be used
without password.
Control mode: The control mode adds the function of operational control interface on the
basis of monitor mode. You need a password to enter the control mode. The initial password is
81338818 (the password can be changed).
Debug mode: On the basis of diagnostic mode, the parameter setting interface is added.
Only Raycus debug engineers can enter the encryption mode.
Diagnostic mode: When a fault occurs in the laser and the user needs to diagnose the fault
remotely or learn more about the status of the laser, the user can enter the diagnostic mode. The
diagnostic mode adds the status and alarm information of
the master module, slave module,
ACDC module and DCDC module
on the basis of the observation mode. You need a password
to enter the diagnostic mode. The initial password is 81338818 (password can be changed).
4.7.8 Main control module
The main control module contains all the status, alarms and system parameters of the main
control module. The status and alarm information are automatically refreshed. The refresh
interval does not exceed 100ms. Only when the currently selected page is in the main control
module, the upper computer software will automatically read it. Get and refresh status and alarm
information, reduce communication frequency, and avoid occupying too many resources of the
main control module.