Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL- RFL-C6600S
51
Table 17 (Continued)
Scattered Light
Alarm
Instruction:
Scattering light alarm, when the intensity of ambient light inside the laser
exceeds the set value, the scattering light alarm will be generated, and the laser
emission function will be locked (cannot be unlocked).The scattered light
alarm only occurs when the laser emission.
Solution:
Please restart the laser, check the guide laser state of the laser, and through the
clientware "from the control module" reading the scattered light monitoring
voltage value, and contact Raycus.
Laser Power Alarm
Instruction:
The alarm is generated when the emission of the laser cannot reach the set
value. Power error occurs only when the laser is emitting.
Solution:
Please restart the laser, check the red light state of the laser,and contact
Raycus.
ACDC Alarm
Instruction:
ACDC Error, failure ofthe laser power supply or sudden power failure of the
power supply system may cause an alarm.
Solution:
Check if the input AC voltage is normal. Restart the laser, if this error
continues to occur, please contact Raycus.
Current Driver
Alarm
Instruction:
Current Driver Alarm,this error occurs when the constant current driver board
inside the laser is abnormal.
Solution:
Restart the laser, If this error continues to occur, please contact Raycus
In addition to the above, if there are any questions or errors inusing of the laser, you can
contactRaycus to get help.
6
Warranty, Return and Maintenance
6.1
General Warranty
Raycus warrants that all Raycus fiber laserproducts are conformed to applicable product
specifications under normal use and are free from defects in materials and workmanship. The
warranties start on the date of shipment from Raycus for a period of time as set forth in the
applicable purchase contracts or product specifications. Raycus has the right to choose to repair or
replace any product that proves to be defective in materials and workmanship selectively during