Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL- RFL-C6600S
27
Control laser parameters: Optical output parameters include power, frequency, pulse width,
and duty cycle.The communication between the software and the main control board requires
only power, frequency, and pulsewidth.The duty cycle can be calculated from the pulse width
and frequency, and the pulse width can also be calculated from the duty cycle and
frequency.During the software operation, the frequency and duty cycle will be changed
synchronously with the pulse width, and the duty cycle will also be changed synchronously with
the frequency and duty cycle.The output power can be an integer in the range of (0,100). The
frequency can be set to a decimal in the range of (0,5000). The duty cycle can be set to a decimal
in the range of (0,100).
Control light emission mode: light emission related modes include AD mode, external
enable, external modulation mode, and internal modulation mode. You can individually control
the opening and closing of each mode, and display the current status of each mode. After the AD
mode is turned on, the optical power is controlled by an external signal, and the power setting
function of the software should be set to a disabled state. When the external modulation mode is
turned on, the frequency, pulse width and duty cycle are controlled by the external modulation
signal, and the function of the software to set the frequency, pulse width and duty cycle should
be set to the disabled state.
Control the light: control to turn on or off the laser emission or laser enable. Only when the
laser has a ready signal, can it be controlled normally, otherwise the buttons for turning on and
off the laser are set to the disabled state. When the external control light enable is turned off, and
the external modulation mode or internal modulation mode is turned on, the "laser enable" is
displayed, otherwise, the "laser emission" is displayed.
Status display: Including emergency stop, laser enable, Interlock logic normal, Interlock1
closed, Interlock2 closed, power ramp up and down, program mode, program execution, program
execution completed, program execution abnormal and other most commonly used laser states,
and machine Internal ambient temperature, internal ambient humidity, dew point, external 0-10V,