26
The control interface is the content displayed on the first page after opening the clientware,
including the user's most commonly used status signal, laser parameter setting and laser control
related functions.
Control the main power: turn on or off the main power. After turning on or off the main
power, the software will change the status of the main power.
Control abnormal laser reset: Click the reset button to run the abnormal laser reset
command.
Guide laser: the guide laser is turned on or off in the internal control state of guide laser.
After the guide laser is turned on or off, there will be changes in the guide laser state on the
software.
Guide laser external control: turn on the guide laser external control or turn off the guide
laser external control. After turning on and turn off the guide laser external control, there will be
changes of the guide laser external control state in the software.If the current red external control
state, then disable the red control button.
Read and set the parameters of rise time and fall time: The rise time and fall time can be set
separately and must be an integer ranging from 0 to 61000.
Read and Set Program Number: The program number is displayed in the drop-down list box.
When you click the drop-down list box, the program number saved on the main control board is
loaded. Only the valid program number is displayed. The default value is "Not set",
corresponding to the program number "0". When you click Read, the current program number is
read from the main control board. If the read program number is ―0‖ and ―unset‖ is displayed,
otherwise, the read program number is displayed. When you click "Set", if "Not set" is selected,
the program number is set to "0", indicating that the program mode is not currently used;
otherwise, the program number is set to the currently selected program number. When the
software is started, the program number set on the current main control board is automatically
read and displayed.