![Raycus RFL-C4000S Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/raycus/rfl-c4000s/rfl-c4000s_user-manual_789676030.webp)
30
Open: The current program
number is not 0.
ON mode
Laser ON -- Start the program to execute
Laser OFF -- Terminate the program
External
modulated modes
in REM mode
INTERFACE24 pin 15, 16 pin voltage:
Rising time -- Start the program to execute
Falling time -- Terminates program running
Close: The current program
number is 0
Do not execute a programming program
When the current program number of the laser is not 0, the laser runs in Program Mode.Please
use the software of Raycus to edit the waveform, and select the program number of pre-run. The
output waveform of laser is determined by the edited waveform. Under the condition that all
working conditions are met, the relation diagram of laser and programming waveform in
programming mode is as follows:
Waveform
switch
:
ONOFF/15,
16 pin
Programming
waveforms
Laser
Figure 14. Relationship between laser and programming waveform in programming mode
4.8.2
The
Programming Setup Interface (Waveform editing)
Select "Show programming mode" in "Mode Selection" on the
clientware
of the laser, and
the "Program Setting" option appears on the display interface of the
clientware
. Click "Program
Setting" to enter the program setting interface, as shown in Figure 15.