22
10
Remote Start
Button
START-A
Instantaneous
Contact Closure
Input
24VDC
<1s
In
REMOTE
mode, start
the laser main power
supply.Passive contact, not
connected to external
voltage or grounding.
11
START-B
12
Analog Input to
Control Current
1-10V
Analog Input
1-10VDC
1 mA
100us
Analog Input 1-10 VDC=
10 – 100% Setpoint
13
Analog Output
Power Monitor
AOUT
Analog Output
0-8VDC
11mA
100µs
Analog Output 0-8 VDC
(
Refer to factory
inspection report for
details
)
14
Isolated
Analog Com
GND1
Return
Return for signals on pins
12, 13,19,22,23,24
15
Mod
MOD+
Digital Input
5-24VDC
6 mA
20µs
5 -24 VDC Input
16
Modulation-
MOD—
Return
Return for signal on pin 15
17
Guided Laser
Control
RED-LASER
Digital Input
5-24Vdc
6 mA
120ms
Positive edge activates
emission in REMOTE
mode
18
Emission
Enable
LAS—C
Digital Input
5-24VDC
6 mA
1ms
Positive edge activates
emission in REMOTE
mode
19
System error
(
ERROR
)
S-ERR
Digital output
24VDC
100mA
120ms
High=System error
20
System
Common
GND2
Return
Return for pin 17
、
18
、
21
21
Error RESET
RESET
Digital Input
5-24VDC
6 mA
120ms
Rising edge reset (the
resettable alarm)
22
READY
READY
Digital output
24VDC
100mA
120ms
High=Laser is ready
22
Power started
POWER
Digital output
24VDC
100mA
120ms
High=
The main power
supply is started
23
Laser emission
LASER
Digital output
24VDC
100mA
100ms
High=Laser is emission
◆
Caution: Please check the control voltage level and ensure that the level is in
accordance with the requirements. Over voltage and voltage ripple may damage
the product.
The Service Security Interface is pin 2-3 and pin 1-4 of CTRL-INTERFACE.
➢
If the pin 2-3 and pin 1-4 are disconnected, the laser will immediately stop emitting light,
and the laser Ready signal output will change to low level. Be sure to short-circuit pin 2-3