![Raycus RFL-C4000S Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/raycus/rfl-c4000s/rfl-c4000s_user-manual_789676025.webp)
Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL- RFL-C4000S
25
(2)
Turn on the chiller and check leakage. If there is no water leakage, turn off the chiller and
wait for the laser to turn on.
(3)
Turn on the air switch and release the emergency stop switch.
Note:
In order to avoid damage the laser caused by condensation when the working
temperature and relative humidity of the laser are in the dew point area [
the blue area in Table 4
].
Enter cold and dry air through the CDA port to discharge the moist air in the cabinet, or improve
the working environment of the laser to make the ambient temperature lower than the internal
temperature of the laser. It is recommended that an independent air conditioner be configured for
the laser.
(4)
Let the chiller work;
(5)
Turn on the key switch and start the laser.
4.7
Functions of the clientware
The RFL-C4000S clientware communicates with the main control board through UDP when
it is working. Through the background program running in the software and the human-computer
interaction operation, the laser parameters are read and set and the control functions are realized.
The interface displayed by the software is divided according to functional categories, including
control, alarm, about, language selection, authorization, working mode selection and other pages.