26
Figure 10 The
clientware interface
4.7.1
The control interface
The control interface is the content displayed on the first page after opening the clientware,
including the user's most commonly used status signal, laser parameter setting and laser control
related functions.
Control the main power: turn on or off the main power. After turning on or off the main power,
the software will change the status of the main power.
Control abnormal laser reset: Click the reset button to run the abnormal laser reset command.
Guide laser: the guide laser is turned on or off in the internal control state of guide laser. After
the guide laser is turned on or off, there will be changes in the guide laser state on the software.
Guide laser external control: turn on the guide laser external control or turn off the guide laser
external control. After turning on and turn off the guide laser external control, there will be changes
of the guide laser external control state in the software.
If the current red external control state,
then disable the red control button.
Read and set the parameters of rise time and fall time: The rise time and fall time can be set
separately and must be an integer ranging from 0 to 61000.